Simulation-Based Framework for Backflashover Rate Estimation in High-Voltage Transmission Lines Integrating Monte-Carlo, ATP-EMTP, and Leader Progression Model
André T. Lobato (),
Liliana Arevalo,
Rodolfo A. R. Moura,
Marco Aurélio O. Schroeder and
Vernon Cooray
Additional contact information
André T. Lobato: Department of Electrical Engineering, Division of Electricity, Uppsala University, Box 65, 751 03 Uppsala, Sweden
Liliana Arevalo: Department of Electrical Engineering, Division of Electricity, Uppsala University, Box 65, 751 03 Uppsala, Sweden
Rodolfo A. R. Moura: Department of Electrical Engineering, Federal University of São João del-Rei (UFSJ), São João del-Rei 36307-352, Brazil
Marco Aurélio O. Schroeder: Department of Electrical Engineering, Federal University of São João del-Rei (UFSJ), São João del-Rei 36307-352, Brazil
Vernon Cooray: Department of Electrical Engineering, Division of Electricity, Uppsala University, Box 65, 751 03 Uppsala, Sweden
Energies, 2025, vol. 18, issue 21, 1-27
Abstract:
Lightning-induced backflashovers pose significant risks to high-voltage transmission systems, particularly in high lightning activity regions. Conventional backflashover rate (BFR) estimation methods rely on simplified empirical formulas that lack accuracy in complex scenarios. This paper presents a comprehensive simulation framework integrating (i) a Simulation-Based Leader Progression Model (SB-LPM) implemented in COMSOL Multiphysics–MATLAB to evaluate lightning attachment through detailed electrostatic field analysis and streamer-leader dynamics, (ii) ATP-EMTP electromagnetic transient simulations incorporating multi-component Heidler function current waveforms, calibrated to regional lightning measurements, and (iii) a Monte Carlo analysis for statistical assessment of backflashover susceptibility. Applied to a representative 138 kV transmission line in Minas Gerais, Brazil, the framework shows that BFR results are highly sensitive to tower-footing impedance and attachment model selection. The SB-LPM yields systematically different predictions compared to traditional electrogeometric models, yielding approximately 10% lower BFR estimates at 20 Ω grounding impedance relative to the widely used Eriksson model. The framework enables comprehensive lightning performance assessment by incorporating geometry-sensitive attachment modeling, realistic current waveform synthesis, and detailed system transient response, providing valuable insights for transmission line insulation coordination studies.
Keywords: backflashover rate; transmission lines; lightning; leader progression model; electromagnetic transients; Monte Carlo; ATP–EMTP; COMSOL (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: Add references at CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/18/21/5670/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/21/5670/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:21:p:5670-:d:1781966
Access Statistics for this article
Energies is currently edited by Ms. Cassie Shen
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().