Research on Arc Extinguishing Characteristics of Single-Phase Grounding Fault in Distribution Network
Yan Li (),
Jianyuan Xu,
Peng Wang and
Guanhua Li
Additional contact information
Yan Li: School of Electrical Engineering, Shenyang University of Technology, Shenyang 110870, China
Jianyuan Xu: School of Electrical Engineering, Shenyang University of Technology, Shenyang 110870, China
Peng Wang: State Grid Liaoning Electric Power Co., Ltd., Shenyang 110004, China
Guanhua Li: State Grid Liaoning Electric Power Co., Ltd., Electric Power Science Research Institute, Shenyang 110055, China
Energies, 2025, vol. 18, issue 2, 1-20
Abstract:
The development of a single-phase grounding fault arc is influenced by various environmental factors, which can result in the rapid extinction and reignition of the arc. This phenomenon can lead to accidents, such as resonant overvoltage. Current grounding arc models inadequately account for the effects of grounding current, arc length, environmental wind speed, and other variables on the characteristics of the arc. In response to this issue, this article establishes a three-dimensional single-phase grounding arc mathematical model grounded in magnetohydrodynamics. It simulates and analyzes the effects of arc length and environmental wind speed on both arc ignition and extinguishing. Furthermore, an artificial single-phase grounding test platform is constructed within the actual distribution network to validate the accuracy of the simulation model. Research has demonstrated that, under identical operating conditions for both simulation and experimentation, the error range between the simulated arc voltage and the measured data is within 8%. The three-dimensional single-phase grounding arc mathematical model effectively describes the dynamic development process of the grounding arc. At a gap of 12 cm, under windless conditions and with a grounding current of 40.0 A, the temperature of the arc column at the peak of the current reaches 2600 K, while the conductivity decreases to 2.1 × 10 −4 S/m, resulting in the inability of the arc to sustain a burning state. At a gap of 2 cm and a wind speed of 7 m/s, the temperature of the arc column at the peak of the current reaches 2900 K, the conductivity drops to 4.3 × 10 −3 S/m, leading to the extinction of the arc.
Keywords: grounding arc; wind speed; magnetohydrodynamics; artificial single-phase grounding test platform; temperature of the arc column (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/18/2/256/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/2/256/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:2:p:256-:d:1562951
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().