Impact Assessment of Grid-Connected Solar Photovoltaic Systems on Power Distribution Grid: A Case Study on a Highly Loaded Feeder in Ulaanbaatar Ger District
Turmandakh Bat-Orgil,
Battuvshin Bayarkhuu,
Bayasgalan Dugarjav () and
Insu Paek
Additional contact information
Turmandakh Bat-Orgil: Department of Green Energy and Engineering, National University of Mongolia, Ulaanbaatar 14201, Mongolia
Battuvshin Bayarkhuu: Department of Green Energy and Engineering, National University of Mongolia, Ulaanbaatar 14201, Mongolia
Bayasgalan Dugarjav: Department of Green Energy and Engineering, National University of Mongolia, Ulaanbaatar 14201, Mongolia
Insu Paek: Department of Integrated Energy and Infra System, Kangwon National University, Chuncheon-si 24341, Republic of Korea
Energies, 2025, vol. 18, issue 2, 1-17
Abstract:
Adopting and widely implementing solar photovoltaic (PV) systems are regarded as a promising solution to address energy crises by providing a sustainable and independent electricity supply while significantly reducing greenhouse gas emissions to combat climate change. This encourages households, organizations, and enterprises to install solar PV systems. However, there are many solar PV systems that have been connected to the power distribution grid without following the required procedures. Power distribution grid operators cannot detect the locations of these solar PV systems. Thus, it is necessary to assess the impact of solar PV systems on the power distribution grid in detail, even though there are multiple economic and environmental advantages associated with installing solar PV systems. This study analyzes the changes in an overloaded power distribution grid’s power losses and voltage deviations with solar PV systems. There are two main factors considered for assessing the impact of the solar PV system on the power distribution grid: the total installed capacity of the solar PV systems and the location of the connection. Based on a comparison between the measurement results of three feeders with higher loads in the Ulaanbaatar area, the Dambadarjaa feeder, which has the highest load, was selected. The impact of the solar PV systems on the selected feeder was analyzed by connecting eight solar PV systems at four different locations. Their total installed capacities vary between 25 and 80 percent of the highest daily load of the selected feeder. The results show that the power loss of the feeder can be greatly reduced when the total installed capacity of the solar PV systems is selected optimally, and the location of the connection is at the end of the power distribution grid.
Keywords: solar photovoltaic systems; power distribution grid; power loss; voltage deviation (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/18/2/440/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/2/440/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:2:p:440-:d:1571326
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().