Abstract:
C-type thermocouples are widely used to measure rich combustions; however, the measured temperature, i.e., the thermocouple junction temperature, is not equal to the gas temperature. The junction temperature results from the junction energy balance, including radiation with environments, conduction with thermocouple wires, and convection with gas. A correction based on the junction energy conservation can derive the gas temperature from the measured temperature. Two C-type thermocouples are used to measure the core region of the standard flames with known gas velocity, composition, and temperature. By matching the CFD-simulated junction temperature with the measured temperature, the emissivity of the thermocouples is obtained. In the temperature range of 1190–1542 K, the emissivity of both thermocouples is close to 0.4. Since the junctions of the C-type thermocouple are large, the area ratios of the wire cross-section to the junction surface are small, and the wire conduction effect is minimal. CFD simulations show that the junction temperatures only decrease by 3.9 K and 8.1 K without wire conduction when the 0.5 mm and 1.0 mm thermocouples measure the Hencken flame with the temperature of 2023.5 K. With the CFD simulation of the measurement of the diffusion region of the Hencken flame, where a strong gas temperature gradient exists, the junction contacting status is judged for the 0.5 mm thermocouple. The simulated temperature of the welding point is consistent with the measured temperature, indicating no wire contact inside the junction.
Keywords: thermocouple; temperature correction; junction contacting status; C-type thermocouple (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/18/3/468/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/3/468/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:3:p:468-:d:1572638
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().