Variable-Speed Hydropower Control and Ancillary Services: A Remedy for Enhancing Grid Stability and Flexibility
Cagatay Cebeci (),
Max Parker,
Luis Recalde-Camacho,
David Campos-Gaona and
Olimpo Anaya-Lara ()
Additional contact information
Cagatay Cebeci: Electronic and Electrical Engineering Department, University of Strathclyde, 204 George St., Glasgow G1 1XW, UK
Max Parker: Electronic and Electrical Engineering Department, University of Strathclyde, 204 George St., Glasgow G1 1XW, UK
Luis Recalde-Camacho: Electronic and Electrical Engineering Department, University of Strathclyde, 204 George St., Glasgow G1 1XW, UK
David Campos-Gaona: Electronic and Electrical Engineering Department, University of Strathclyde, 204 George St., Glasgow G1 1XW, UK
Olimpo Anaya-Lara: Electronic and Electrical Engineering Department, University of Strathclyde, 204 George St., Glasgow G1 1XW, UK
Energies, 2025, vol. 18, issue 3, 1-35
Abstract:
Variable-Speed Hydropower Plants (VSHP) are becoming more promising for stabilising power grids with the increasing integration of renewable energy sources. This research focuses on improving fault ride-through capabilities and delivering efficient ancillary services for VSHPs to support the grid by developing a comprehensive control strategy. The control system proposed integrates a machine-side controller, a Frequency Support Controller (FSC), a Virtual Synchronous Machine (VSM), a Vector Current Controller (VCC) for the grid-side converter, a turbine governor for regulating turbine speed, and a DC-link controller. PID with an anti-windup scheme and a Model Predictive Controller (MPC) were employed for the turbine governor. The MPC turbine governor results demonstrate the potential of advanced control methods for enhanced performance of the VSHP. A benchmarking between the MPC and the PID governor was made. The benchmarking results have reported that the MPC can achieve reference tracking improvements up to 99.42 % . Tests on a diverse set of grid scenarios were conducted, and the graphical results showed significant improvements in mitigating the frequency drops through the effective governor response. The synthetic inertia provision is swift, completing within seconds of a frequency drop. Compared to the fixed-speed approach, the VSHP improves the grid’s overall stability by minimising frequency dipping and achieving steady-state recovery remarkably faster. The fixed-speed approach only begins to recover minutes after the VSHP reaches the settling time. By effectively providing critical ancillary services such as frequency support, synthetic inertia, and smooth fault ride-through capability, the VSHP can become a transformative solution for future power grids, which are estimated to be more reliant on renewable energy sources.
Keywords: Frequency Support Control (FSC); Grid Stability; Model Predictive Control (MPC); Renewable Energy Integration; Variable-Speed Hydropower (VSHP) (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/18/3/642/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/3/642/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:3:p:642-:d:1580485
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().