Overvoltage Simulation Analysis and Suppression of Breaking in a 35 kV Shunt Reactor

Jing Chen, Xiaoyue Chen, Siying Feng (), Xinmeng Liu and Qin Liu
Additional contact information
Jing Chen: Beijing Electric Power Economic and Technological Research Institute Co., Ltd., Beijing 100055, China
Xiaoyue Chen: School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
Siying Feng: School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
Xinmeng Liu: Beijing Electric Power Economic and Technological Research Institute Co., Ltd., Beijing 100055, China
Qin Liu: Beijing Electric Power Economic and Technological Research Institute Co., Ltd., Beijing 100055, China

Energies, 2025, vol. 18, issue 5, 1-17

Abstract: When a 35 kV distribution network has the problem of insufficient reactive power, the input of a shunt reactor is a common compensation method. Vacuum circuit breakers are widely used in 35 kV distribution networks because of their superior arc extinguishing performance and convenient maintenance. However, in recent years, accidents involving vacuum circuit breakers breaking shunt reactors have occurred more frequently in China, such as high-frequency phase-to-phase short circuits, inter-turn burning losses, bus outlet short circuits, etc., which can cause serious damage and pose a greater threat to the safety of the power system. This paper focuses on the switching overvoltage generated by the vacuum circuit breaker cutting off the shunt reactor. Firstly, the mechanism of overvoltage generation is analyzed theoretically. It is concluded that the equivalent chopping current of the other two phases caused by the continuous reignition of the first open phase is the root cause of the high-amplitude interphase overvoltage. Based on the MODELS custom programming module in EMTP/ATP, according to the process of breaking and reigniting the circuit breaker, this paper uses Fortran language to compile the program and establishes a model of a vacuum circuit breaker, including power frequency current interception, high-frequency current, zero-crossing, breaking, and arc reignition modules. The vacuum circuit breaker is simulated for hundreds of continuous reignitions in milliseconds. Finally, a simulation study on the overvoltage suppression measures of a 35 kV shunt reactor is carried out. The comprehensive comparison of various suppression measures provides a reference for the reasonable selection of actual engineering conditions.

Keywords: reactor; vacuum circuit breaker; interrupt shunt reactor overvoltage; equivalent closure; overvoltage suppression measures (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: Add references at CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/18/5/1274/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/5/1274/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:5:p:1274-:d:1605906

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-22
Handle: RePEc:gam:jeners:v:18:y:2025:i:5:p:1274-:d:1605906