EconPapers    
Economics at your fingertips  
 

Research on the Liquid Helium Insulation Characteristics of an Experimental System

Ye Chen, Liang Guo, Qiming Jia, Xiujuan Xie (), Weiping Zhu and Ping Wang
Additional contact information
Ye Chen: Key Laboratory of Cryogenic Science and Technology, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
Liang Guo: Key Laboratory of Cryogenic Science and Technology, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
Qiming Jia: Key Laboratory of Cryogenic Science and Technology, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
Xiujuan Xie: Key Laboratory of Cryogenic Science and Technology, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
Weiping Zhu: Key Laboratory of Cryogenic Science and Technology, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China
Ping Wang: Key Laboratory of Cryogenic Science and Technology, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, China

Energies, 2025, vol. 18, issue 6, 1-20

Abstract: The research on the thermal insulation performance of experimental systems in the liquid helium temperature range is relatively scarce. This paper presents the theoretical design and establishment of a liquid helium storage system for insulation research, consisting of a liquid helium Dewar, a daily boil-off rate test subsystem, and a helium recovery subsystem. The passive thermal insulation structure consisted of a multilayer insulation (MLI) system with hollow glass microspheres serving as spacers. Based on self-built data acquisition, experiments were conducted to investigate the liquid helium insulation characteristics of an experimental system. A theoretical thermal analysis of the Dewar was conducted, resulting in the derivation of an expression for the heat leak of the Dewar. The analysis indicates that the evaporation capacity from the liquid helium Dewar was significantly affected by the structure of the neck tube. The overall relative error between the simulated and experimental temperature distribution of the insulation layer is 14.3%, with a maximum error of 22.3%. The system had an average daily boil-off rate of 14.4%, a heat leakage of 7.5 W, and a heat flux of 2.254 W/m 2 , while the effective thermal conductivity of the MLI with hollow glass microspheres was determined to be 2.887 × 10 −4 W/(m·K). Furthermore, the apparent thermal conductivity between different layers of MLI significantly fluctuated with increasing temperature, ranging from a maximum of 5.342 × 10 −4 W/(m·K) to a minimum of 1.721 × 10 −4 W/(m·K).

Keywords: liquid helium; thermal insulation characteristics; hollow glass microspheres; daily boil-off rate; multilayer insulation (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: Add references at CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/18/6/1349/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/6/1349/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:6:p:1349-:d:1608671

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-22
Handle: RePEc:gam:jeners:v:18:y:2025:i:6:p:1349-:d:1608671