EconPapers    
Economics at your fingertips  
 

Modeling, Validation and Analysis of the Performance of Direct Air-Cooling Condensers for Mountainous Terrain

Xubo Lu, Hongyi Chen, Jingyao Wang, Huimin Wei () and Xiaoze Du
Additional contact information
Xubo Lu: Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, North China Electric Power University, Ministry of Education, Beijing 102206, China
Hongyi Chen: China Nuclear Power Engineering Co., Ltd., Beijing 100840, China
Jingyao Wang: Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, North China Electric Power University, Ministry of Education, Beijing 102206, China
Huimin Wei: Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, North China Electric Power University, Ministry of Education, Beijing 102206, China
Xiaoze Du: Key Laboratory of Condition Monitoring and Control for Power Plant Equipment, North China Electric Power University, Ministry of Education, Beijing 102206, China

Energies, 2025, vol. 18, issue 8, 1-35

Abstract: Direct air-cooling systems use air instead of water as a cooling medium, so they are easily affected by meteorological and hydrological conditions. In this paper, considering the complex geographic conditions around the direct air-cooling units, Gambit is used to model the direct air-cooling system, including the complex mountainous terrain, and the performance simulation of the direct air-cooling system and the complex mountainous terrain near the power plant is realized by combining the CFD method with the MATLAB mathematical model of the power plant. Through the simulation, the operation of the ACC system under various meteorological conditions is obtained, and the influence of environmental factors and complex geographic conditions on the performance of the ACC system is investigated and further analyzed for the special case of the back-furnace wind. On this basis, a clustering analysis algorithm was used to obtain the results of turbine zoning in different wind directions and to analyze the physical field shifts of the units caused by geographic factors.

Keywords: direct air-cooling system; fan shaft power; mountainous terrain; cooling performance; back pressure; clustering analysis; power plant (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: Add references at CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1996-1073/18/8/2010/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/8/2010/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:8:p:2010-:d:1634602

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-04-15
Handle: RePEc:gam:jeners:v:18:y:2025:i:8:p:2010-:d:1634602