Grid-Connected Harmonic Suppression Strategy Considering Phase-Locked Loop Phase-Locking Error Under Asymmetrical Faults
Yanjiu Zhang and
Shuxin Tian ()
Additional contact information
Yanjiu Zhang: College of Electrical Engineering, Shanghai University of Electric Power, Shanghai 200090, China
Shuxin Tian: Offshore Wind Power Research Institute, Shanghai University of Electric Power, Shanghai 200090, China
Energies, 2025, vol. 18, issue 9, 1-24
Abstract:
Harmonic distortion caused by phase jumps in the phase-locked loop (PLL) during asymmetric faults poses a significant threat to the secure operation of renewable energy grid-connected systems. A harmonic suppression strategy based on Vague set theory is proposed for offshore wind power AC transmission systems. By employing the three-dimensional membership framework of Vague sets—comprising true, false, and hesitation degrees—phase-locked errors are characterized, and dynamic, real-time PLL proportional-integral (PI) parameters are derived. This approach addresses the inadequacy of harmonic suppression in conventional PLL, where fixed PI parameters limit performance under asymmetric faults. The significance of this research is reflected in the improved power quality of offshore wind power grid integration, the provision of technical solutions supporting efficient clean energy utilization in alignment with “Dual Carbon” objectives, and the introduction of innovative approaches to harmonic suppression in complex grid environments. Firstly, an equivalent circuit model of the offshore wind power AC transmission system is established, and the impact of PLL phase jumps on grid harmonics during asymmetric faults is analyzed in conjunction with PLL locking mechanisms. Secondly, Vague sets are employed to model the phase-locked error interval across three dimensions, enabling adaptive PI parameter tuning to suppress harmonic content during such faults. Finally, time-domain simulations conducted in PSCAD indicate that the proposed Vague set-based control strategy reduces total harmonic distortion (THD) to 1.08%, 1.12%, and 0.97% for single-phase-to-ground, two-phase-to-ground, and two-phase short-circuit faults, respectively. These values correspond to relative reductions of 13.6%, 33.7%, and 80.87% compared to conventional control strategies, thereby confirming the efficacy of the proposed method in minimizing grid-connected harmonic distortions.
Keywords: asymmetric faults; vague set; interval control; harmonic content (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/18/9/2202/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/9/2202/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:9:p:2202-:d:1643008
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().