Use of Capacitive Probes to Detect Asymmetry and Earth Fault in a Medium-Voltage Power Network
Krzysztof Walczak () and
Aleksandra Schött-Szymczak
Additional contact information
Krzysztof Walczak: Institute of Electric Power Engineering, Poznan University of Technology, 60-965 Poznan, Poland
Aleksandra Schött-Szymczak: Institute of Electric Power Engineering, Poznan University of Technology, 60-965 Poznan, Poland
Energies, 2025, vol. 18, issue 9, 1-16
Abstract:
The detection of short circuits in a medium-voltage (MV) network is a complex issue due to the way the neutral point works. An additional difficulty is the relatively large load asymmetry. The methods used so far include complex equipment (e.g., a system of voltage transformers) for use mainly in power stations. The detection of short circuits deep in the network is therefore difficult, and this could facilitate the process of fault localization and limit the areas that should be disconnected for the time of fault removal. This article presents the new concept of using a system of capacitive probes as a simple and cheap tool that allows for the detection of a short circuit in an MV network based on the assessment of the zero-voltage component. This component is considered to be one of the basic starting criteria for various types of specialist earth-fault protections. Appropriately placed capacitive probes—through the existence of capacitive coupling with phase conductors—record the voltages of individual phases, including the total resultant voltage, which is the criterion for detecting a short circuit in the system. An important advantage of using such a solution is that capacitive probes allow for voltage measurement and assessment of line asymmetry in a non-contact and, therefore, safe manner. The presented concept has been tested in the laboratory and supported by simulation studies. The modeling of the system was based on the parameters of real structures used in overhead lines, recreated in laboratory conditions. Obtaining positive results of the simulation studies—primarily the appropriate sensitivity of short-circuit detection, confirmed in the laboratory—allows for the creation of a prototype of the device and the commencement of field tests, which will be the subject of further work conducted by the authors.
Keywords: MV network; earth fault; capacitive probe; diagnostics; medium-voltage overhead lines (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2025
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1996-1073/18/9/2254/pdf (application/pdf)
https://www.mdpi.com/1996-1073/18/9/2254/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:18:y:2025:i:9:p:2254-:d:1645003
Access Statistics for this article
Energies is currently edited by Ms. Agatha Cao
More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().