EconPapers    
Economics at your fingertips  
 

Determination of Steady-State and Faulty Regimes of Overhead Lines by Means of Multiconductor Cell Analysis (MCA)

Roberto Benato, Sebastian Dambone Sessa and Fabio Guglielmi
Additional contact information
Roberto Benato: Department of Industrial Engineering, University of Padova, Via Gradenigo, 6/A, Padova 35131, Italy
Sebastian Dambone Sessa: Department of Industrial Engineering, University of Padova, Via Gradenigo, 6/A, Padova 35131, Italy
Fabio Guglielmi: Department of Industrial Engineering, University of Padova, Via Gradenigo, 6/A, Padova 35131, Italy

Energies, 2012, vol. 5, issue 8, 1-23

Abstract: Single-phase positive sequence modelling is often used in power systems when power flows and short circuit analysis are assessed. Of course, the use of single-phase positive sequence modelling assumes purely three-phase configurations and perfectly symmetrical ones so that single-phase modelling considers that all the phase conductors behave in the same way. When considering the physical reality of power networks, this assumption can be questionable and the behaviors of all the system conductors including the passive ones (earth wires for overhead lines, metallic screens and armours for cables and enclosures for gas insulated lines) is completely unknown. Therefore, the present multiconductor cell analysis (MCA) becomes necessary, since it allows one to achieve great precision results on the regimes of both phase conductors and passive conductors. MCA offers a powerful tool in order to validate (or less) approximated and simplified computation methods. In particular, for single and double circuit overhead lines (OHLs), the current phasors induced in the earth wires and the ground return current alongside the line can be directly computed by MCA in steady state and faulty regimes. It is worth noting that, for faulty regimes, MCA allows also evaluating the approximation degree and validity field of screening factors k.

Keywords: overhead line; multiconductor cell analysis; extra high voltage; voltage and current behaviors (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2012
References: View complete reference list from CitEc
Citations: View citations in EconPapers (4)

Downloads: (external link)
https://www.mdpi.com/1996-1073/5/8/2771/pdf (application/pdf)
https://www.mdpi.com/1996-1073/5/8/2771/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:5:y:2012:i:8:p:2771-2793:d:19180

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:5:y:2012:i:8:p:2771-2793:d:19180