EconPapers    
Economics at your fingertips  
 

Assessment of the Economic and Environmental Impact of Double Glazed Façade Ventilation Systems in Mediterranean Climates

David Valentín, Alfredo Guardo, Eduard Egusquiza, Carme Valero and Pere Alavedra
Additional contact information
David Valentín: Center for Industrial Diagnostics and Fluid Dynamics (CDIF), Polytechnic University of Catalonia (UPC), Av. Diagonal, 647 ETSEIB, 08028 Barcelona, Spain
Alfredo Guardo: Center for Industrial Diagnostics and Fluid Dynamics (CDIF), Polytechnic University of Catalonia (UPC), Av. Diagonal, 647 ETSEIB, 08028 Barcelona, Spain
Eduard Egusquiza: Center for Industrial Diagnostics and Fluid Dynamics (CDIF), Polytechnic University of Catalonia (UPC), Av. Diagonal, 647 ETSEIB, 08028 Barcelona, Spain
Carme Valero: Center for Industrial Diagnostics and Fluid Dynamics (CDIF), Polytechnic University of Catalonia (UPC), Av. Diagonal, 647 ETSEIB, 08028 Barcelona, Spain
Pere Alavedra: International University of Catalonia, C\Immaculada 22, 08017 Barcelona, Spain

Energies, 2013, vol. 6, issue 10, 1-19

Abstract: Free convection is the most often used method in order to reduce solar load gains on a building with double glazed façades (DGFs). However, depending on the climate factors, the thermal performance of a DGF may not be satisfactory and extra energy costs are required to obtain suitable comfort conditions inside the building. Forced ventilation systems are a feasible alternative to improve the thermal performance of a DGF in Mediterranean climates where large solar gains are a permanent condition throughout the year. In this paper the feasibility of using diverse forced ventilation methods in DGF is evaluated. In addition, an economical comparison between different mechanical ventilation systems was performed in order to demonstrate the viability of DGF forced ventilation. Moreover, an environmental study was carried out to prove the positive energetic balance on cooling loads between free and forced convection in DGF for Mediterranean climates. For this investigation, a CFD model was used to simulate the thermal conditions in a DGF for the different ventilation systems. Results obtained for heat flux, temperature and reductions in solar load gains were analyzed and applied for the economic and environmental research.

Keywords: double glazed façades (DGF); Coand? nozzle; forced convection; building thermal performance; cooling load savings; environmental impact (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2013
References: View complete reference list from CitEc
Citations: View citations in EconPapers (3)

Downloads: (external link)
https://www.mdpi.com/1996-1073/6/10/5069/pdf (application/pdf)
https://www.mdpi.com/1996-1073/6/10/5069/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:6:y:2013:i:10:p:5069-5087:d:29225

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:6:y:2013:i:10:p:5069-5087:d:29225