EconPapers    
Economics at your fingertips  
 

Low Voltage Ride-through in DFIG Wind Generators by Controlling the Rotor Current without Crowbars

Jaime Rodríguez Arribas, Adrián Fernández Rodríguez, Ángel Hermoso Muñoz and Carlos Veganzones Nicolás
Additional contact information
Jaime Rodríguez Arribas: Department of Electrical Engineering, ETS Ingenieros Industriales, Universidad Politécnica de Madrid, Jose Gutiérrez Abascal 2, 28006 Madrid, Spain
Adrián Fernández Rodríguez: Institute for Research in Technology, Pontifical Comillas University, Alberto Aguilera 23, 28015 Madrid, Spain
Ángel Hermoso Muñoz: Department of Electrical Engineering, ETS Ingenieros Industriales, Universidad Politécnica de Madrid, Jose Gutiérrez Abascal 2, 28006 Madrid, Spain
Carlos Veganzones Nicolás: Department of Electrical Engineering, ETS Ingenieros Industriales, Universidad Politécnica de Madrid, Jose Gutiérrez Abascal 2, 28006 Madrid, Spain

Energies, 2014, vol. 7, issue 2, 1-22

Abstract: Among all the different types of electric wind generators, those that are based on doubly fed induction generators, or DFIG technology, are the most vulnerable to grid faults such as voltage sags. This paper proposes a new control strategy for this type of wind generator, that allows these devices to withstand the effects of a voltage sag while following the new requirements imposed by grid operators. This new control strategy makes the use of complementary devices such as crowbars unnecessary, as it greatly reduces the value of currents originated by the fault. This ensures less costly designs for the rotor systems as well as a more economic sizing of the necessary power electronics. The strategy described here uses an electric generator model based on space-phasor theory that provides a direct control over the position of the rotor magnetic flux. Controlling the rotor magnetic flux has a direct influence on the rest of the electrical variables enabling the machine to evolve to a desired work point during the transient imposed by the grid disturbance. Simulation studies have been carried out, as well as test bench trials, in order to prove the viability and functionality of the proposed control strategy.

Keywords: DFIG wind generators; low voltage ride through (LVRT) capability; voltage sag; voltage dip (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2014
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (5)

Downloads: (external link)
https://www.mdpi.com/1996-1073/7/2/498/pdf (application/pdf)
https://www.mdpi.com/1996-1073/7/2/498/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:7:y:2014:i:2:p:498-519:d:32415

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jeners:v:7:y:2014:i:2:p:498-519:d:32415