EconPapers    
Economics at your fingertips  
 

Improved Performance of Electrical Transmission Tower Structure Using Connected Foundation in Soft Ground

Doohyun Kyung, Youngho Choi, Sangseom Jeong and Junhwan Lee
Additional contact information
Doohyun Kyung: School of Civil and Environmental Engineering, Yonsei University, 134 Shinchon-dong, Seodaemun-gu, Seoul 120-749, Korea
Youngho Choi: KTP Consultants Pte Ltd., E-Centre@Redhill, 3791 Jalan Bukit Merah, Singapore 159471, Singapore
Sangseom Jeong: School of Civil and Environmental Engineering, Yonsei University, 134 Shinchon-dong, Seodaemun-gu, Seoul 120-749, Korea
Junhwan Lee: School of Civil and Environmental Engineering, Yonsei University, 134 Shinchon-dong, Seodaemun-gu, Seoul 120-749, Korea

Energies, 2015, vol. 8, issue 6, 1-20

Abstract: A connected foundation is an effective foundation type that can improve the structural performance of electrical transmission towers in soft ground as a resilient energy supply system with improved stability. In the present study, the performance of a connected foundation for transmission towers was investigated, focusing on the effect of connection beam properties and soil conditions. For this purpose, a finite element analysis was performed for various foundation and soil conditions. In order to validate the finite element analysis, the calculated results were compared with measured results obtained from field load tests. The use of connection beams was more effective for uplift foundations that usually control the design of transmission tower foundations. For the effect of soil condition, the use of connected foundation is more effective in soft clays with lower undrained shear strength (s u ). Smaller amounts of differential settlement were observed in all soil conditions for both unconnected and connected foundations when a bearing rock layer was present. When the foundation was not reinforced by connection beams, the values of lateral load capacity of tower structure ( H u ) were similar for both with- and without-rock layers. It was confirmed that introducing haunch-shaped connection beams is effective for increasing connection beam stability.

Keywords: resilient energy infrastructure system; electrical transmission tower structures; connected foundation; soft grounds; field load test; finite element analysis (search for similar items in EconPapers)
JEL-codes: Q Q0 Q4 Q40 Q41 Q42 Q43 Q47 Q48 Q49 (search for similar items in EconPapers)
Date: 2015
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1996-1073/8/6/4963/pdf (application/pdf)
https://www.mdpi.com/1996-1073/8/6/4963/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jeners:v:8:y:2015:i:6:p:4963-4982:d:50298

Access Statistics for this article

Energies is currently edited by Ms. Agatha Cao

More articles in Energies from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19