EconPapers    
Economics at your fingertips  
 

Exposure to Air Ions in Indoor Environments: Experimental Study with Healthy Adults

Peter Wallner, Michael Kundi, Michael Panny, Peter Tappler and Hans-Peter Hutter
Additional contact information
Peter Wallner: Institute of Environmental Health, Center for Public Health, , Medical University Vienna, Kinderspitalgasse 15, Vienna 1090, Austria
Michael Kundi: Institute of Environmental Health, Center for Public Health, , Medical University Vienna, Kinderspitalgasse 15, Vienna 1090, Austria
Michael Panny: Institute of Environmental Health, Center for Public Health, , Medical University Vienna, Kinderspitalgasse 15, Vienna 1090, Austria
Peter Tappler: Austrian Institute for Healthy and Ecological Building, Alserbachstraße 5, Vienna 1090, Austria
Hans-Peter Hutter: Institute of Environmental Health, Center for Public Health, , Medical University Vienna, Kinderspitalgasse 15, Vienna 1090, Austria

IJERPH, 2015, vol. 12, issue 11, 1-11

Abstract: Since the beginning of the 20th century there has been a scientific debate about the potential effects of air ions on biological tissues, wellbeing and health. Effects on the cardiovascular and respiratory system as well as on mental health have been described. In recent years, there has been a renewed interest in this topic. In an experimental indoor setting we conducted a double-blind cross-over trial to determine if higher levels of air ions, generated by a special wall paint, affect cognitive performance, wellbeing, lung function, and cardiovascular function. Twenty healthy non-smoking volunteers (10 female, 10 male) participated in the study. Levels of air ions, volatile organic compounds and indoor climate factors were determined by standardized measurement procedures. Air ions affected the autonomous nervous system (in terms of an increase of sympathetic activity accompanied by a small decrease of vagal efferent activity): In the test room with higher levels of air ions (2194/cm 3 vs. 1038/cm 3 ) a significantly higher low to high frequency ratio of the electrocardiography (ECG) beat-to-beat interval spectrogram was found. Furthermore, six of nine subtests of a cognitive performance test were solved better, three of them statistically significant (verbal factor, reasoning, and perceptual speed), in the room with higher ion concentration. There was no influence of air ions on lung function and on wellbeing. Our results indicate slightly activating and cognitive performance enhancing effects of a short-term exposure to higher indoor air ion concentrations.

Keywords: air ions; cognitive performance; heart rate variability; lung function; indoor air; wellbeing (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2015
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)

Downloads: (external link)
https://www.mdpi.com/1660-4601/12/11/14301/pdf (application/pdf)
https://www.mdpi.com/1660-4601/12/11/14301/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:12:y:2015:i:11:p:14301-14311:d:58545

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:12:y:2015:i:11:p:14301-14311:d:58545