Impact of a Risk Management Plan on Legionella Contamination of Dental Unit Water
Erica Leoni,
Laura Dallolio,
Francesca Stagni,
Tiziana Sanna,
Giovanni D'Alessandro and
Gabriela Piana
Additional contact information
Erica Leoni: Department of Biomedical and Neuromotor Sciences, Unit of Hygiene, Public Health and Medical Statistics, University of Bologna, via San Giacomo 12, 40126, Bologna, Italy
Laura Dallolio: Department of Biomedical and Neuromotor Sciences, Unit of Hygiene, Public Health and Medical Statistics, University of Bologna, via San Giacomo 12, 40126, Bologna, Italy
Francesca Stagni: Department of Biomedical and Neuromotor Sciences, Unit of Odontostomatological Sciences, University of Bologna, via San Vitale 59, 40125, Bologna, Italy
Tiziana Sanna: Department of Biomedical and Neuromotor Sciences, School of Hygiene and Preventive Medicine, University of Bologna, via San Giacomo 12, 40126, Bologna, Italy
Giovanni D'Alessandro: Department of Biomedical and Neuromotor Sciences, Unit of Odontostomatological Sciences, University of Bologna, via San Vitale 59, 40125, Bologna, Italy
Gabriela Piana: Department of Biomedical and Neuromotor Sciences, Unit of Odontostomatological Sciences, University of Bologna, via San Vitale 59, 40125, Bologna, Italy
IJERPH, 2015, vol. 12, issue 3, 1-15
Abstract:
The study aimed to assess the prevalence of Legionella spp. in dental unit waterlines of a dental clinic and to verify whether the microbiological parameters used as indicators of water quality were correlated with Legionella contamination. A risk management plan was subsequently implemented in the dental health care setting, in order to verify whether the adopted disinfection protocols were effective in preventing Legionella colonization. The water delivered from syringes and turbines of 63 dental units operating in a dental clinic, was monitored for counts of the heterotrophic bacteria P. aeruginosa and Legionella spp. (22 °C and 37 °C). At baseline, output water from dental units continuously treated with disinfection products was more compliant with the recommended standards than untreated and periodically treated water. However, continuous disinfection was still not able to prevent contamination by Legionella and P. aeruginosa . Legionella was isolated from 36.4%, 24.3% and 53.3% of samples from untreated, periodically and continuously treated waterlines, respectively. The standard microbiological parameters used as indicators of water quality proved to be unreliable as predictors of the presence of Legionella , whose source was identified as the tap water used to supply the dental units. The adoption of control measures, including the use of deionized water in supplying the dental unit waterlines and the application of a combined protocol of continuous and periodic disinfection, with different active products for the different devices, resulted in good control of Legionella contamination. The efficacy of the measures adopted was mainly linked to the strict adherence to the planned protocols, which placed particular stress on staff training and ongoing environmental monitoring.
Keywords: Legionella spp.; dental unit waterlines; dental unit disinfection; dental unit water safety plan (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2015
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (8)
Downloads: (external link)
https://www.mdpi.com/1660-4601/12/3/2344/pdf (application/pdf)
https://www.mdpi.com/1660-4601/12/3/2344/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:12:y:2015:i:3:p:2344-2358:d:46093
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().