Occupant Interactions and Effectiveness of Natural Ventilation Strategies in Contemporary New Housing in Scotland, UK
Tim Sharpe,
Paul Farren,
Stirling Howieson,
Paul Tuohy and
Jonathan McQuillan
Additional contact information
Tim Sharpe: Mackintosh Environmental Architecture Research Unit, Glasgow School of Art, 167 Renfrew Street, Glasgow G3 6RQ, UK
Paul Farren: ASSIST Design Architects, 100 Kerr Street, Glasgow G40 2QP, UK
Stirling Howieson: ESRU/Department of Architecture, University of Strathclyde, James Weir Building, 75 Montrose Street, Glasgow G1 1XJ, UK
Paul Tuohy: ESRU/Department of Architecture, University of Strathclyde, James Weir Building, 75 Montrose Street, Glasgow G1 1XJ, UK
Jonathan McQuillan: Anderson Bell Christie, 382 Great Western Road, Glasgow G4 9HT, UK
IJERPH, 2015, vol. 12, issue 7, 1-18
Abstract:
The need to reduce carbon emissions and fuel poverty has led to increased building envelope air tightness, intended to reduce uncontrolled ventilation heat losses. Ventilation strategies in dwellings still allow the use of trickle ventilators in window frames for background ventilation. The extent to which this results in “healthy” Indoor Air Quality (IAQ) in recently constructed dwellings was a concern of regulators in Scotland. This paper describes research to explore this. First a review of literature was conducted, then data on occupant interactions with ventilation provisions (windows, doors, trickle vents) gathered through an interview-based survey of 200 recently constructed dwellings, and measurements made on a sample of 40 of these. The main measured parameter discussed here is CO 2 concentration. It was concluded after the literature review that 1000 ppm absolute was a reasonable threshold to use for “adequate” ventilation. The occupant survey found that there was very little occupant interaction with the trickle ventilators e.g., in bedrooms 63% were always closed, 28% always open, and in only 9% of cases occupants intervened to make occasional adjustments. In the measured dwellings average bedroom CO 2 levels of 1520 ppm during occupied (night time) hours were observed. Where windows were open the average bedroom CO 2 levels were 972 ppm. With windows closed, the combination of “trickle ventilators open plus doors open” gave an average of 1021 ppm. “Trickle ventilators open” gave an average of 1571 ppm. All other combinations gave averages of 1550 to 2000 ppm. Ventilation rates and air change rates were estimated from measured CO 2 levels, for all dwellings calculated ventilation rate was less than 8 L/s/p, in 42% of cases calculated air change rate was less than 0.5 ach. It was concluded that trickle ventilation as installed and used is ineffective in meeting desired ventilation rates, evidenced by high CO 2 levels reported across the sampled dwellings. Potential implications of the results are discussed.
Keywords: ventilation; IAQ; housing; bedrooms, CO 2; building regulations, trickle ventilators (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2015
References: View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1660-4601/12/7/8480/pdf (application/pdf)
https://www.mdpi.com/1660-4601/12/7/8480/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:12:y:2015:i:7:p:8480-8497:d:52914
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI