EconPapers    
Economics at your fingertips  
 

Time Effectiveness of Ultraviolet C Light (UVC) Emitted by Light Emitting Diodes (LEDs) in Reducing Stethoscope Contamination

Gabriele Messina, Mattia Fattorini, Nicola Nante, Daniele Rosadini, Andrea Serafini, Marco Tani and Gabriele Cevenini
Additional contact information
Gabriele Messina: Laboratory of Environmental Hygiene, Department of Molecular and Developmental Medicine, University of Siena, Via Aldo Moro 2, 53100 Siena, Italy
Mattia Fattorini: Post Graduate School of Public Health, University of Siena, Via Aldo Moro 2, 53100 Siena, Italy
Nicola Nante: Laboratory of Environmental Hygiene, Department of Molecular and Developmental Medicine, University of Siena, Via Aldo Moro 2, 53100 Siena, Italy
Daniele Rosadini: Post Graduate School of Public Health, University of Siena, Via Aldo Moro 2, 53100 Siena, Italy
Andrea Serafini: Post Graduate School of Public Health, University of Siena, Via Aldo Moro 2, 53100 Siena, Italy
Marco Tani: FeT Elettronica S.n.c Via A. Volta 28, 53036 Poggibonsi (Siena), Italy
Gabriele Cevenini: Department of Medical Biotechnologies, University of Siena, Via Aldo Moro 2, 53100 Siena, Italy

IJERPH, 2016, vol. 13, issue 10, 1-8

Abstract: Today it is well demonstrated that stethoscopes can be as contaminated as hands, which are a recognized source of Health-Care Associated Infections (HCAIs). Ultraviolet C (UVC) light has proven disinfection capacity and the innovative UVC technology of Light Emitting Diode (LED) shows several potential benefits. To verify whether the use of UVC LEDs is effective and reliable in stethoscope membrane disinfection after prolonged use, a pre-post intervention study was conducted. A total of 1668 five-minute cycles were performed on two UVC LEDs to simulate their use; thereafter, their disinfection capacity was tested on stethoscope membranes used on a previously auscultated volunteer. Then, a further 1249 cycles were run and finally the LEDs were tested to assess performance in reducing experimental contamination by Staphylococcus aureus , Pseudomonas aeruginosa and Escherichia coli on the stethoscope membrane. Baseline volunteer contamination identified 104 Colony Forming Units (CFUs) while treated Petri dishes had 12 and 15 CFUs ( p < 0.001). Statistically significant differences ( p < 0.001) were also found relating to the reduction of specific bacteria: in particular, after treatment no CFU were observed for S. aureus and E. coli . UVC LEDs demonstrated the capacity to maintain high levels of disinfection after more than 240 h of use and they were effective against common microorganisms that are causative agents of HCAIs.

Keywords: disinfection; ultraviolet; LED; stethoscope; health-care associated infections (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2016
References: View complete reference list from CitEc
Citations: View citations in EconPapers (6)

Downloads: (external link)
https://www.mdpi.com/1660-4601/13/10/940/pdf (application/pdf)
https://www.mdpi.com/1660-4601/13/10/940/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:13:y:2016:i:10:p:940-:d:78748

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-24
Handle: RePEc:gam:jijerp:v:13:y:2016:i:10:p:940-:d:78748