Investigation of Indoor Air Quality in Houses of Macedonia
Silvia Vilčeková,
Ilija Zoran Apostoloski,
Ľudmila Mečiarová,
Eva Krídlová Burdová and
Jozef Kiseľák
Additional contact information
Silvia Vilčeková: Institute of Environmental Engineering, Faculty of Civil Engineering, Technical University of Košice, Vysokoškolská 4, 04200 Košice, Slovakia
Ilija Zoran Apostoloski: Institute of Environmental Engineering, Faculty of Civil Engineering, Technical University of Košice, Vysokoškolská 4, 04200 Košice, Slovakia
Ľudmila Mečiarová: Institute of Environmental Engineering, Faculty of Civil Engineering, Technical University of Košice, Vysokoškolská 4, 04200 Košice, Slovakia
Eva Krídlová Burdová: Institute of Environmental Engineering, Faculty of Civil Engineering, Technical University of Košice, Vysokoškolská 4, 04200 Košice, Slovakia
Jozef Kiseľák: Institute of Mathematics, Faculty of Science, Pavol Jozef Šafárik University in Košice, Jesenná 5, 04001 Košice, Slovakia
IJERPH, 2017, vol. 14, issue 1, 1-12
Abstract:
People who live in buildings are exposed to harmful effects of indoor air pollution for many years. Therefore, our research is aimed to investigate the indoor air quality in family houses. The measurements of indoor air temperature, relative humidity, total volatile organic compounds (TVOC), particulate matters (PM) and sound pressure level were carried out in 25 houses in several cities of the Republic of Macedonia. Mean values of indoor air temperature and relative humidity ranged from 18.9 °C to 25.6 °C and from 34.1% to 68.0%, respectively. With regard to TVOC, it can be stated that excessive occurrence was recorded. Mean values ranged from 50 ?g/m 3 to 2610 ?g/m 3 . Recommended value (200 ?g/m 3 ) for human exposure to TVOC was exceeded in 32% of houses. Mean concentrations of PM 2.5 (particular matter with diameter less than 2.5 ?m) and PM 10 (diameter less than 10 ?m) are determined to be from 16.80 ?g/m 3 to 30.70 ?g/m 3 and from 38.30 ?g/m 3 to 74.60 ?g/m 3 individually. Mean values of sound pressure level ranged from 29.8 dB(A) to 50.6 dB(A). Dependence between characteristics of buildings (Year of construction, Year of renovation, Smoke and Heating system) and data from measurements (Temperature, Relative humidity, TVOC, PM 2.5 and PM 10 ) were analyzed using R software. Van der Waerden test shows dependence of Smoke on TVOC and PM 2.5 . Permutational multivariate analysis of variance shows the effect of interaction of Renovation and Smoke.
Keywords: family house; temperature; humidity; TVOC; PM; sound pressure level; statistical analysis (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2017
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (4)
Downloads: (external link)
https://www.mdpi.com/1660-4601/14/1/37/pdf (application/pdf)
https://www.mdpi.com/1660-4601/14/1/37/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:14:y:2017:i:1:p:37-:d:86729
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().