Exposure Modelling of Extremely Low-Frequency Magnetic Fields from Overhead Power Lines and Its Validation by Measurements
Alfred Bürgi,
Sanjay Sagar,
Benjamin Struchen,
Stefan Joss and
Martin Röösli
Additional contact information
Alfred Bürgi: ARIAS umwelt.forschung.beratung gmbh, Gutenbergstrasse 40B, 3011 Bern, Switzerland
Sanjay Sagar: Swiss Tropical and Public Health Institute, Department of Epidemiology and Public Health, Socinstrasse 57, 4051 Basel, Switzerland
Benjamin Struchen: Swiss Tropical and Public Health Institute, Department of Epidemiology and Public Health, Socinstrasse 57, 4051 Basel, Switzerland
Stefan Joss: Federal Office for the Environment (FOEN), 3003 Bern, Switzerland
Martin Röösli: Swiss Tropical and Public Health Institute, Department of Epidemiology and Public Health, Socinstrasse 57, 4051 Basel, Switzerland
IJERPH, 2017, vol. 14, issue 9, 1-19
Abstract:
A three-dimensional model for calculating long term exposure to extremely low-frequency magnetic fields from high-voltage overhead power lines is presented, as well as its validation by measurements. For the validation, the model was applied to two different high-voltage overhead power lines in Iffwil and Wiler (Switzerland). In order to capture the daily and seasonal variations, each measurement was taken for 48 h and the measurements were carried out six times at each site, at intervals of approximately two months, between January and December 2015. During each measurement, a lateral transect of the magnetic flux density was determined in the middle of a span from nine measurement points in the range of ±80 m. The technical data of both the lines as well as the load flow data during the measurement periods were provided by the grid operators. These data were used to calculate 48 h averages of the absolute value of the magnetic flux density and compared with modelled values. The highest 48 h average was 1.66 µT (centre of the line in Iffwil); the lowest 48 h average was 22 nT (80 m distance from the centre line in Iffwil). On average, the magnetic flux density was overestimated by 2% (standard deviation: 9%) in Iffwil and underestimated by 1% (8%) in Wiler. Sensitivity analyses showed that the uncertainty is mainly driven by errors in the coordinates and height data. In particular, for predictions near the centre of the line, an accurate digital terrain model is critical.
Keywords: high-voltage power lines; magnetic fields; extremely low frequency; exposure model; measurement (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2017
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1660-4601/14/9/949/pdf (application/pdf)
https://www.mdpi.com/1660-4601/14/9/949/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:14:y:2017:i:9:p:949-:d:109428
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().