EconPapers    
Economics at your fingertips  
 

Portable Analyzer for On-Site Determination of Dissolved Organic Carbon—Development and Field Testing

Heinrich Glorian, Viktor Schmalz, Paweł Lochyński, Paul Fremdling, Hilmar Börnick, Eckhard Worch and Thomas Dittmar
Additional contact information
Heinrich Glorian: Institute of Water Chemistry, Technische Universität Dresden, 01069 Dresden, Germany
Viktor Schmalz: Institute of Water Chemistry, Technische Universität Dresden, 01069 Dresden, Germany
Paweł Lochyński: Institute of Environmental Engineering, Wrocław University of Environmental and Life Sciences, 50-375 Wrocław, Poland
Paul Fremdling: Institute of Water Chemistry, Technische Universität Dresden, 01069 Dresden, Germany
Hilmar Börnick: Institute of Water Chemistry, Technische Universität Dresden, 01069 Dresden, Germany
Eckhard Worch: Institute of Water Chemistry, Technische Universität Dresden, 01069 Dresden, Germany
Thomas Dittmar: Institute of Water Chemistry, Technische Universität Dresden, 01069 Dresden, Germany

IJERPH, 2018, vol. 15, issue 11, 1-13

Abstract: Dissolved organic carbon (DOC) is a sum parameter that is frequently used in water analytics. Highly resolved and accurate DOC data are necessary, for instance, for water quality monitoring and for the evaluation of the efficiency of treatment processes. The conventional DOC determination methods consist of on-site sampling and subsequent analysis in a stationary device in a laboratory. However, especially in regions where no or only poorly equipped laboratories are available, this method bears the risk of getting erroneous results. For this reason, the objective of the present study was to set up a reliable and portable DOC analyzer for on-site analysis. The presented DOC system is equipped with an electrolysis-based decomposition cell with boron-doped diamond electrodes (BDD) that oxidizes the organic compounds to carbon dioxide. Within this study, the influence of different electrode materials and the composition of the applied electrolytes on the DOC decomposition in an undivided electrolytic cell were systematically investigated. Furthermore, some technical aspects of the portable prototype are discussed. After a detailed validation, the prototype was used in an ongoing monitoring program in Northern India. The limit of detection is 0.1 mg L −1 C with a relative standard deviation of 2.3% in a linear range up to 1000 mg L C −1 . The key features of the portable DOC analyzer are: No need for ultra-pure gases, catalysts or burning technology, an analyzing time per sample below 5 min, and a reliable on-site DOC determination.

Keywords: DOC; on-site analysis; electro-oxidation; BDD; hydroxyl radicals; in-situ carrier gas (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2018
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1660-4601/15/11/2335/pdf (application/pdf)
https://www.mdpi.com/1660-4601/15/11/2335/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:15:y:2018:i:11:p:2335-:d:177667

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:15:y:2018:i:11:p:2335-:d:177667