EconPapers    
Economics at your fingertips  
 

Domain-Specific Adult Sedentary Behaviour Questionnaire (ASBQ) and the GPAQ Single-Item Question: A Reliability and Validity Study in an Asian Population

Anne H. Y. Chu, Sheryl H. X. Ng, David Koh and Falk Müller-Riemenschneider
Additional contact information
Anne H. Y. Chu: Saw Swee Hock School of Public Health, National University of Singapore, Singapore 117549, Singapore
Sheryl H. X. Ng: Saw Swee Hock School of Public Health, National University of Singapore, Singapore 117549, Singapore
David Koh: Saw Swee Hock School of Public Health, National University of Singapore, Singapore 117549, Singapore
Falk Müller-Riemenschneider: Saw Swee Hock School of Public Health, National University of Singapore, Singapore 117549, Singapore

IJERPH, 2018, vol. 15, issue 4, 1-13

Abstract: This study examined the validity and reliability of a domain-specific Adult Sedentary Behaviour Questionnaire (ASBQ) and the Global Physical Activity Questionnaire (GPAQ) single-item sitting question using self- and interviewer-administered modes of administration against the triaxial ActiGraph wGT3X-BT accelerometer. The ASBQ and the GPAQ were administered twice, seven days apart. Participants were asked to put on the waist-worn accelerometer for seven days. Convergent validity was assessed using Spearman’s rho, mean absolute error (MAE), and Bland-Altman analysis ( n = 78). Reliability was assessed using the Spearman’s rho and intraclass correlation coefficient (ICC) ( n = 84). Participants were adults aged 20–65 years and identifying as Chinese, Malay, or Indian. Only the self-administered GPAQ was significantly correlated with accelerometry-based measures (rho: 0.46), but not the interviewer-administered version (rho: 0.12). MAE for GPAQ was 207.5–218.3 min/day in relation to the accelerometer and for ASBQ was 154.7–174.6 min/day. Bland-Altman plots demonstrated large limits of agreement between questionnaire and accelerometry-based measures. While the self-administered GPAQ demonstrated a moderate correlation with accelerometry, the mean bias and the limits of agreement were large. The GPAQ (rho: 0.68–0.79; ICC: 0.68–0.78) and the ASBQ (rho: 0.53–0.64; ICC: 0.66–0.74) showed moderate-to-good reliability for total sedentary time using either self- or interviewer-administration. Future research should incorporate accelerometers to generate useful sedentary behaviour measures.

Keywords: accelerometers; measurement; psychometrics; questionnaires; validation (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2018
References: View complete reference list from CitEc
Citations: View citations in EconPapers (9)

Downloads: (external link)
https://www.mdpi.com/1660-4601/15/4/739/pdf (application/pdf)
https://www.mdpi.com/1660-4601/15/4/739/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:15:y:2018:i:4:p:739-:d:140779

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:15:y:2018:i:4:p:739-:d:140779