EconPapers    
Economics at your fingertips  
 

Solid Particle Number (SPN) Portable Emissions Measurement Systems (PEMS) in the European Legislation: A Review

Barouch Giechaskiel, Pierre Bonnel, Adolfo Perujo and Panagiota Dilara
Additional contact information
Barouch Giechaskiel: European Commission, Joint Research Centre, 21027 Ispra, Italy
Pierre Bonnel: European Commission, Joint Research Centre, 21027 Ispra, Italy
Adolfo Perujo: European Commission, Joint Research Centre, 21027 Ispra, Italy
Panagiota Dilara: European Commission, DG-GROW, 1040 Brussels, Belgium

IJERPH, 2019, vol. 16, issue 23, 1-23

Abstract: Portable emissions measurement systems (PEMS) for gaseous pollutants were firstly introduced in the United States regulation to check the in-use compliance of heavy-duty engines, avoiding the high costs of removing the engine and testing it on a dynamometer in the laboratory. In Europe, the in-service conformity of heavy-duty engines has been checked with PEMS for gaseous pollutants since 2014. To strengthen emissions regulations with a view to minimise the differences between on-road and laboratory emission levels in some cases, PEMS testing, including solid particle number (SPN), was introduced for the type-approval of light-duty vehicles in Europe in 2017 and for in-service conformity in 2019. SPN-PEMS for heavy-duty engines will be introduced in 2021. This paper gives an overview of the studies for SPN-PEMS from early 2013 with the first prototypes until the latest testing and improvements in 2019. The first prototype diffusion charger (DC) based systems had high differences from the reference laboratory systems at the first light-duty vehicles campaign. Tightening of the technical requirements and improvements from the instrument manufacturers resulted in differences of around 50%. Similar differences were found in an inter-laboratory comparison exercise with the best performing DC- and CPC- (condensation particle counter) based system. The heavy-duty evaluation phase at a single lab and later at various European laboratories revealed higher differences due to the small size of the urea generated particles and their high charge at elevated temperatures. This issue, along with robustness at low ambient temperatures, was addressed by the instrument manufacturers bringing the measurement uncertainty to the 50% levels. This measurement uncertainty needs to be considered at the on-road emission results measured with PEMS.

Keywords: air pollution; vehicle emissions; on-road testing; portable emissions measurement systems (PEMS); real-driving emissions (RDE); solid particle number; particle measurement programme (PMP); sub-23 nm (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2019
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (8)

Downloads: (external link)
https://www.mdpi.com/1660-4601/16/23/4819/pdf (application/pdf)
https://www.mdpi.com/1660-4601/16/23/4819/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:16:y:2019:i:23:p:4819-:d:292600

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:16:y:2019:i:23:p:4819-:d:292600