EconPapers    
Economics at your fingertips  
 

Filter Cassette Method for Analyzing Man-Made Vitreous Fibers Settled on Surfaces

Tapani Tuomi, Jyrki Kilpikari, Minna Hartonen, Reima Kämppi and Heli Lallukka
Additional contact information
Tapani Tuomi: Finnish Institute of Occupational Health, Topeliuksenkatu 41 B, P.O. Box 40, Työterveyslaitos, FI-00032 Helsinki, Finland
Jyrki Kilpikari: Finnish Institute of Occupational Health, Topeliuksenkatu 41 B, P.O. Box 40, Työterveyslaitos, FI-00032 Helsinki, Finland
Minna Hartonen: Finnish Institute of Occupational Health, Topeliuksenkatu 41 B, P.O. Box 40, Työterveyslaitos, FI-00032 Helsinki, Finland
Reima Kämppi: Finnish Institute of Occupational Health, Topeliuksenkatu 41 B, P.O. Box 40, Työterveyslaitos, FI-00032 Helsinki, Finland
Heli Lallukka: Finnish Institute of Occupational Health, Topeliuksenkatu 41 B, P.O. Box 40, Työterveyslaitos, FI-00032 Helsinki, Finland

IJERPH, 2019, vol. 16, issue 7, 1-12

Abstract: A new method was developed to analyze the surface count of fibers in a variety of environments. The method entails sampling surfaces with the help of suction to a filter cassette holder containing a cellulose filter. The filters were collapsed using microwave digestion in dilute acid, and the fibers filtered to polycarbonate filters, gilded, and analyzed by scanning electron microscopy (SEM). The method was compared to traditional gel tape sampling as described in International Standards Organization (ISO) standard 16000-27, following analysis with phase contrast microscopy. The methods were compared in industrial environments and in office-type environments, with the concentration range studied spanning from 0.1 to 100,000 fibers/cm 2 . The methods yielded similar results ( p < 0.05) in concentrations from 100 to 10,000 cfu/cm 2 , while the filter cassette method gave systematically higher results in high concentrations (>10,000 cfu/cm 2 ) as well as in all office-type environments studied, where the fiber count ranged from 0.1 to 20 fibers/cm 2 . Consequently, we recommend using the new method in working environments where the surface count is more than 100 fibers/cm 2 , as well as in office-type environments where the fiber count is below 10 fibers/cm 2 . It should be noted, however, that a similar limit of quantitation as with the gel tape method (0.1 fibers/cm 2 ) requires sampling a minimum area of 100 × 100 cm 2 with the fiber cassette method. Using the filter cassette method will require new guide values to be formed for office-type environments, since the results are higher than with the gel tape method. Alternatively, if present guide values or limit values are to be used with the filter cassette method, conventions as to which fiber sizes to count should be set, since SEM analysis in any case will allow for including a larger size range than phase contrast microscopy (PM). We, however, recommend against such an approach, since fibers less than 1 µm in width may not be less harmful by inhalation than larger fibers.

Keywords: exposure assessment; man-made vitreous fibers; MMVF; surface sampling (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2019
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1660-4601/16/7/1256/pdf (application/pdf)
https://www.mdpi.com/1660-4601/16/7/1256/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:16:y:2019:i:7:p:1256-:d:221016

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:16:y:2019:i:7:p:1256-:d:221016