Simulation of Air Puff Tonometry Test Using Arbitrary Lagrangian–Eulerian (ALE) Deforming Mesh for Corneal Material Characterisation
Osama Maklad,
Ashkan Eliasy,
Kai-Jung Chen,
Vassilios Theofilis and
Ahmed Elsheikh
Additional contact information
Osama Maklad: School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
Ashkan Eliasy: School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
Kai-Jung Chen: School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
Vassilios Theofilis: School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
Ahmed Elsheikh: School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
IJERPH, 2019, vol. 17, issue 1, 1-21
Abstract:
Purpose: To improve numerical simulation of the non-contact tonometry test by using arbitrary Lagrangian-Eulerian deforming mesh in the coupling between computational fluid dynamics model of an air jet and finite element model of the human eye. Methods: Computational fluid dynamics model simulated impingement of the air puff and employed Spallart–Allmaras model to capture turbulence of the air jet. The time span of the jet was 30 ms and maximum Reynolds number was R e = 2.3 × 10 4 , with jet orifice diameter 2.4 mm and impinging distance 11 mm. The model of the human eye was analysed using finite element method with regional hyperelastic material variation and corneal patient-specific topography starting from stress-free configuration. The cornea was free to deform as a response to the air puff using an adaptive deforming mesh at every time step of the solution. Aqueous and vitreous humours were simulated as a fluid cavity filled with incompressible fluid with a density of 1000 kg/m 3 . Results: Using the adaptive deforming mesh in numerical simulation of the air puff test improved the traditional understanding of how pressure distribution on cornea changes with time of the test. There was a mean decrease in maximum pressure (at corneal apex) of 6.29 ± 2.2% and a development of negative pressure on a peripheral corneal region 2–4 mm away from cornea centre. Conclusions: The study presented an improvement of numerical simulation of the air puff test, which will lead to more accurate intraocular pressure (IOP) and corneal material behaviour estimation. The parametric study showed that pressure of the air puff is different from one model to another, value-wise and distribution-wise, based on cornea biomechanical parameters.
Keywords: Ocular biomechanics; Intraocular pressure (IOP); Fluid–Structure Interaction (FSI); Arbitrary Lagrangian–Eulerian mesh (ALE) (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2019
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1660-4601/17/1/54/pdf (application/pdf)
https://www.mdpi.com/1660-4601/17/1/54/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:17:y:2019:i:1:p:54-:d:299998
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().