Optimizing Operating Parameters of High-Temperature Steam for Disinfecting Total Nematodes and Bacteria in Soil: Application of the Box?Behnken Design
Da-An Huh,
Woo Ri Chae,
Hong Lyuer Lim,
Joung Ho Kim,
Yoo Sin Kim,
Young-Whan Kim and
Kyong Whan Moon
Additional contact information
Da-An Huh: Department of Health Science, Korea University, Anam-ro 145, Seongbuk-gu, Seoul 02841, Korea
Woo Ri Chae: Department of Health and Safety Convergence Science, Korea University, Anam-ro 145, Seongbuk-gu, Seoul 02841, Korea
Hong Lyuer Lim: Department of Health and Safety Convergence Science, Korea University, Anam-ro 145, Seongbuk-gu, Seoul 02841, Korea
Joung Ho Kim: Department of Technology Research and Development, JSE Inc., Muyeol-ro 39, Suseong-gu, Daegu 42033, Korea
Yoo Sin Kim: Department of Technology Research and Development, JSE Inc., Muyeol-ro 39, Suseong-gu, Daegu 42033, Korea
Young-Whan Kim: Department of Technology Research and Development, JSE Inc., Muyeol-ro 39, Suseong-gu, Daegu 42033, Korea
Kyong Whan Moon: Department of Health and Safety Convergence Science, Korea University, Anam-ro 145, Seongbuk-gu, Seoul 02841, Korea
IJERPH, 2020, vol. 17, issue 14, 1-17
Abstract:
Concerns about the widespread use of pesticides have been growing due to the adverse effects of chemicals on the environment and human health. It has prompted worldwide research into the development of a replacement to chemical disinfection of soil. The efficiency of steam sterilization, an alternative to chemical methods, has improved as technology has advanced, and the Agricultural Research and Extension Service in Korea recommends the use of steam sterilization. However, few studies have been conducted on the effects and operating conditions of high-temperature steam disinfection. In this study, we present the optimum operating conditions of a high-steam disinfector, to maximize the cost-effectiveness and removal efficiency of total nematodes and total bacteria in soil using the Box−Behnken design. The experimental data were fitted to a second-order polynomial equation using multiple regression analysis, with coefficients of determination (R2) for each model of 0.9279, 0.9678, and 0.9979. The optimum conditions were found to be a steam temperature of 150.56 °C, running speed of 1.69 m/min, and spray depth of 15.0 cm, with a corresponding desirability value of 0.8367. In the model, these conditions cause the prediction of the following responses: nematode removal efficiency of 93.99%, bacteria removal efficiency of 97.49%, and oil consumption of 70.49 mL/m 2 . At the optimum conditions for the steam disinfector, the removal efficiencies of nematodes and bacteria were maximized, and the oil consumption was minimized. The results of our study can be used as basic data for efficient soil disinfection using high-temperature steam.
Keywords: Box?Behnken design; high-temperature steam disinfection; total nematode; removal efficiency; total bacteria (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2020
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1660-4601/17/14/5029/pdf (application/pdf)
https://www.mdpi.com/1660-4601/17/14/5029/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:17:y:2020:i:14:p:5029-:d:383919
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().