Passive-Type Radon Monitor Constructed Using a Small Container for Personal Dosimetry
Yuki Tamakuma,
Chutima Kranrod,
Takahito Suzuki,
Yuki Watanabe,
Thamaborn Ploykrathok,
Ryoju Negami,
Eka Djatnika Nugraha,
Kazuki Iwaoka,
Mirosław Janik,
Masahiro Hosoda and
Shinji Tokonami
Additional contact information
Yuki Tamakuma: Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Honcho, Hirosaki, Aomori 036-8564, Japan
Chutima Kranrod: Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Honcho, Hirosaki, Aomori 036-8564, Japan
Takahito Suzuki: Graduate School of Health Sciences, Hirosaki University, 66-1 Honcho, Hirosaki, Aomori 036-8564, Japan
Yuki Watanabe: School of Health Sciences, Hirosaki University, 66-1 Honcho, Hirosaki, Aomori 036-8564, Japan
Thamaborn Ploykrathok: Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Honcho, Hirosaki, Aomori 036-8564, Japan
Ryoju Negami: Graduate School of Health Sciences, Hirosaki University, 66-1 Honcho, Hirosaki, Aomori 036-8564, Japan
Eka Djatnika Nugraha: Graduate School of Health Sciences, Hirosaki University, 66-1 Honcho, Hirosaki, Aomori 036-8564, Japan
Kazuki Iwaoka: National Institutes for Quantum and Radiological Science and Technology, 4-9-1 Anagawa, Inage, Chiba 263-0024, Japan
Mirosław Janik: National Institutes for Quantum and Radiological Science and Technology, 4-9-1 Anagawa, Inage, Chiba 263-0024, Japan
Masahiro Hosoda: Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Honcho, Hirosaki, Aomori 036-8564, Japan
Shinji Tokonami: Institute of Radiation Emergency Medicine, Hirosaki University, 66-1 Honcho, Hirosaki, Aomori 036-8564, Japan
IJERPH, 2020, vol. 17, issue 16, 1-11
Abstract:
The International Commission on Radiological Protection (ICRP) recently recommended a new dose conversion factor for radon based on the latest epidemiological studies and dosimetric model. It is important to evaluate an inhalation dose from radon and its progeny. In the present study, a passive radon personal monitor was designed using a small container for storing contact lenses and its performance was evaluated. The conversion factor for radon ( 222 Rn), the effect of thoron ( 220 Rn) concentration and the air exchange rate were evaluated using the calibration chamber at Hirosaki University. The minimum and maximum detectable radon concentrations were calculated. The conversion factor was evaluated as 2.0 ± 0.3 tracks cm −2 per kBq h m −3 ; statistical analyses of results showed no significant effect from thoron concentration. The minimum and maximum detectable radon concentrations were 92 Bq m −3 and 231 kBq m −3 for a measurement period of three months, respectively. The air exchange rate was estimated to be 0.26 ± 0.16 h −1 , whose effect on the measured time-integrated radon concentration was small. These results indicate that the monitor could be used as a wearable monitor for radon measurements, especially in places where radon concentrations may be relatively high, such as mines and caves.
Keywords: passive radon monitor; development; sensitivity; detection limit; air-exchange rate (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2020
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1660-4601/17/16/5660/pdf (application/pdf)
https://www.mdpi.com/1660-4601/17/16/5660/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:17:y:2020:i:16:p:5660-:d:395014
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().