EconPapers    
Economics at your fingertips  
 

The Effect of Different Cleaning Protocols of Polymer-Based Prosthetic Materials on the Behavior of Human Gingival Fibroblasts

Vygandas Rutkunas, Rokas Borusevicius, Dominyka Liaudanskaite, Urte Jasinskyte, Saulius Drukteinis, Virginija Bukelskiene and Eitan Mijiritsky
Additional contact information
Vygandas Rutkunas: Institute of Odontology, Faculty of Medicine, Vilnius University, 03101 Vilnius, Lithuania
Rokas Borusevicius: Institute of Odontology, Faculty of Medicine, Vilnius University, 03101 Vilnius, Lithuania
Dominyka Liaudanskaite: Institute of Odontology, Faculty of Medicine, Vilnius University, 03101 Vilnius, Lithuania
Urte Jasinskyte: Institute of Biochemistry, Life Sciences Center, Vilnius University, 03101 Vilnius, Lithuania
Saulius Drukteinis: Institute of Odontology, Faculty of Medicine, Vilnius University, 03101 Vilnius, Lithuania
Virginija Bukelskiene: Institute of Biochemistry, Life Sciences Center, Vilnius University, 03101 Vilnius, Lithuania
Eitan Mijiritsky: Head and Neck and Maxillofacial Surgery, Department of Otolaryngology, Tel-Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel-Aviv 6997801, Israel

IJERPH, 2020, vol. 17, issue 21, 1-17

Abstract: Dental implant abutment and prosthetic materials, their surface treatment, and cleaning modalities are important factors for the formation of a peri-implant soft tissue seal and long-term stability of bone around the implant. This study aimed to investigate the influence of a polymeric material surface cleaning method on the surface roughness, water contact angle, and human gingival fibroblasts (HGF) proliferation. Polymeric materials tested: two types of milled polymethylmethacrylate (PMMA-Ker and PMMA-Bre), three-dimensionally (3D) printed polymethylmethacrylate (PMMA-3D), polyetheretherketone (PEEK), and polyetherketoneketone (PEKK). Titanium (Ti) and zirconia oxide ceramics (ZrO-HT) were used as positive controls. A conventional surface cleaning protocol (CCP) was compared to a multi-step research cleaning method (RCP). Application of the RCP method allowed to reduce S a values in all groups from 0.14–0.28 µm to 0.08–0.17 µm ( p < 0.05 in PMMA-Ker and PEEK groups). Moreover, the water contact angle increased in all groups from 74–91° to 83–101° ( p < 0.05 in the PEKK group), except ZrO-HT—it was reduced from 98.7 ± 4.5° to 69.9 ± 6.4° ( p < 0.05). CCP resulted in higher variability of HGF viability after 48 and 72 h. RCP application led to higher HGF viability in PMMA-3D and PEKK groups after 48 h, but lower for the PMMA-Ker group ( p < 0.05). After 72 h, no significant differences in HGF viability between both cleaning methods were observed. It can be concluded that the cleaning method of the polymeric materials affected surface roughness, contact angle, and HGF viability at 48 h.

Keywords: polymers; surface; roughness; contact angle; fibroblasts; proliferation; PMMA; PEEK; PEKK; cleaning (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2020
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)

Downloads: (external link)
https://www.mdpi.com/1660-4601/17/21/7753/pdf (application/pdf)
https://www.mdpi.com/1660-4601/17/21/7753/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:17:y:2020:i:21:p:7753-:d:433773

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:17:y:2020:i:21:p:7753-:d:433773