Influence of Connection Type and Platform Diameter on Titanium Dental Implants Fatigue: Non-Axial Loading Cyclic Test Analysis

Ana I. Nicolas-Silvente, Eugenio Velasco-Ortega, Ivan Ortiz-Garcia, Alvaro Jimenez-Guerra, Loreto Monsalve-Guil, Raul Ayuso-Montero, Javier Gil and Jose Lopez-Lopez
Additional contact information
Ana I. Nicolas-Silvente: Periodontal and Implant Surgery, CEIR Campus Mare Nostrum, School of Dentistry, University of Murcia, 30008 Murcia, Spain
Eugenio Velasco-Ortega: Comprehensive Dentistry for Adults and Gerodontology, Faculty of Dentistry, University of Seville, 41009 Seville, Spain
Ivan Ortiz-Garcia: Comprehensive Dentistry for Adults and Gerodontology, Faculty of Dentistry, University of Seville, 41009 Seville, Spain
Alvaro Jimenez-Guerra: Comprehensive Dentistry for Adults and Gerodontology, Faculty of Dentistry, University of Seville, 41009 Seville, Spain
Loreto Monsalve-Guil: Comprehensive Dentistry for Adults and Gerodontology, Faculty of Dentistry, University of Seville, 41009 Seville, Spain
Raul Ayuso-Montero: Faculty of Dentistry, University of Barcelona, 08007 Barcelona, Spain
Javier Gil: Chairman of Bioengineering Institute of Technology, Universitat Internacional de Catalunya, 08017 Barcelona, Spain
Jose Lopez-Lopez: Faculty of Dentistry, Service of the Medical-Surgical Area of Dentistry Hospital, University of Barcelona, 08007 Barcelona, Spain

IJERPH, 2020, vol. 17, issue 23, 1-12

Abstract: Two-pieces dental implants must provide stability of the implant-abutment-interface. The connection type and platform diameter could influence the biomechanical resistance and stress distribution. This study aims to evaluate the fatigue for different types of connections, external and internal, and different platform diameters. Three implant designs with the same length were used: (a) external hexagon/narrow platform; (b) internal double hexagon/narrow platform; (c) internal octagon/regular platform. A fatigue test was developed to establish the number of cycles needed before fracture. A 30º oblique load with a sinusoidal function of fatigue at a frequency of 15 Hz and 10% stress variation was applied to each system. The fatigue load limit (FLL) for design (a) was 190 N, being the nominal-curvature-moment (NCM) = 1.045; FLL = 150 N, with a NCM = 0.825 for (b), and FLL = 325 N, with a NCM = 1.788 for (c). The platform diameter affects the FLL, obtaining lower FLL on a narrow platform. The connection type interferes with the implant walls’ width, especially in narrow implants, making internal connections more unstable at this level. Long-term clinical studies to assess the restoration’s success rate and survival are mandatory.

Keywords: connection type; dental implants; design; fatigue test; platform diameter (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2020
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1660-4601/17/23/8988/pdf (application/pdf)
https://www.mdpi.com/1660-4601/17/23/8988/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:17:y:2020:i:23:p:8988-:d:455249

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:17:y:2020:i:23:p:8988-:d:455249