EconPapers    
Economics at your fingertips  
 

Variable Strength in Thoron Interference for a Diffusion-Type Radon Monitor Depending on Ventilation of the Outer Air

Yasutaka Omori, Michikuni Shimo, Miroslaw Janik, Tetsuo Ishikawa and Hidenori Yonehara
Additional contact information
Yasutaka Omori: Department of Radiation Physics and Chemistry, Fukushima Medical University, 1 Hikarigaoka, Fukushima 960-1295, Japan
Michikuni Shimo: Fujita Health University, 1-98 Dengakugakubo, Kutsukake, Toyoake, Aichi 470-1192, Japan
Miroslaw Janik: Center for Advanced Radiation Emergency Medicine, National Institutes for Quantum and Radiological Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan
Tetsuo Ishikawa: Department of Radiation Physics and Chemistry, Fukushima Medical University, 1 Hikarigaoka, Fukushima 960-1295, Japan
Hidenori Yonehara: Nuclear Safety Research Association, 5-18-7 Shimbashi, Minato-ku, Tokyo 105-0004, Japan

IJERPH, 2020, vol. 17, issue 3, 1-9

Abstract: Thoron interference in radon measurements using passive diffusion radon detectors/monitors is a crucial problem when it comes to assessing the internal exposure to radon precisely. The present study reported, as one of the potential factors, the effects of air flow conditions on changes in thoron interference. Rates of thoron infiltration (as thoron interference) into the diffusion chamber of the monitor were evaluated. The temporal variation was obtained based on measurements of the underfloor space of a Japanese wooden dwelling using a diffusion-type radon monitor, a reference radon monitor which was not affected by thoron interference, and a thoron monitor. The thoron infiltration rate for the diffusion-type monitor varied from 0% to 20%. In particular, it appeared to increase when ventilation of the underfloor space air was forced. The variable thoron infiltration rate, with respect to ventilation strength, implied that not only a diffusive process, but also an advective process, played a major role in air exchange between the diffusion chamber of the monitor and the outer air. When an exposure room is characterized by the frequent variation in air ventilation, a variable thoron response is considered to occur in radon–thoron discriminative detectors, in which only diffusive entry is employed as a mechanism for the discrimination of radon and thoron.

Keywords: air exchange; diffusion; filter; infiltration; passive monitor; radon; thoron interference; ventilation (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2020
References: View complete reference list from CitEc
Citations: View citations in EconPapers (2)

Downloads: (external link)
https://www.mdpi.com/1660-4601/17/3/974/pdf (application/pdf)
https://www.mdpi.com/1660-4601/17/3/974/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:17:y:2020:i:3:p:974-:d:316498

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:17:y:2020:i:3:p:974-:d:316498