EconPapers    
Economics at your fingertips  
 

A Novel Technique Using Polytetrafluoroethylene Tape to Solve Screw Loosening Complication in Implant-Supported Single Crowns

Luis F. Félix, Michell Medina, Cristina Gómez-Polo, Rubén Agustín-Panadero, Rocío Ortega and Miguel Gómez-Polo
Additional contact information
Luis F. Félix: Department of Prosthodontics and Restorative Dentistry, School of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain
Michell Medina: Department of Prosthodontics and Restorative Dentistry, School of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain
Cristina Gómez-Polo: Department of Surgery, Faculty of Medicine, University of Salamanca, 37007 Salamanca, Spain
Rubén Agustín-Panadero: Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain
Rocío Ortega: Department of Prosthetic Dentistry, School of Dentistry, European University of Madrid, 28045 Madrid, Spain
Miguel Gómez-Polo: Department of Prosthetic Dentistry, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain

IJERPH, 2020, vol. 18, issue 1, 1-10

Abstract: This study aimed to analyze a novel technique to make screws with greater untightening resistance and to solve screw loosening in implant-supported single crowns. Thirty grade IV titanium straight abutments were screwed onto 30 external hex implants using grade IV titanium screws (30 Ncm). They were exposed to cyclic loading (300,000 cycles, 200 N). Samples were divided into 4 groups (15 samples per group): new screws (SCREW group) (control), reused screws (rSCREW group), new screws wrapped with polytetrafluoroethylene (PTFE) tape (PTFE group), and reused screws wrapped with PTFE tape (rPTFE group). Reverse torque values (RTVs) were recorded with a digitally calibrated implant motor. Mean RTVs observed were 14.46 N (±1.10 N) for the control group, 14.42 N (±1.22 N) for the rSCREW group, 19.97 N (±1.16 N) for the PTFE group, and 19.13 N (±2.38 N) for the rPTFE group. Statistically significant differences were found between RTVs of both groups employing screws without PTFE tape (SCREW and rSCREW groups) compared with those using screws wrapped with PTFE tape (PTFE and rPTFE) ( p < 0.001). These results suggest that wrapping the implant–abutment screw with PTFE tape may effectively lower the risk of loosening and even constitute a solution when this complication occurs in implant single crowns.

Keywords: screw loosening; implant single crowns; fixed dental prosthesis; polytetrafluorethylene; mechanical complications (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2020
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1660-4601/18/1/125/pdf (application/pdf)
https://www.mdpi.com/1660-4601/18/1/125/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:18:y:2020:i:1:p:125-:d:468894

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:18:y:2020:i:1:p:125-:d:468894