Operational Performance and Load Flexibility Analysis of Japanese Zero Energy House
Xiaoyi Zhang,
Weijun Gao,
Yanxue Li,
Zixuan Wang,
Yoshiaki Ushifusa and
Yingjun Ruan
Additional contact information
Xiaoyi Zhang: Innovation Institute for Sustainable Maritime Architecture Research and Technology, Qingdao University of Technology, Fushun Road 11, Qingdao 266033, China
Weijun Gao: Innovation Institute for Sustainable Maritime Architecture Research and Technology, Qingdao University of Technology, Fushun Road 11, Qingdao 266033, China
Yanxue Li: Innovation Institute for Sustainable Maritime Architecture Research and Technology, Qingdao University of Technology, Fushun Road 11, Qingdao 266033, China
Zixuan Wang: Innovation Institute for Sustainable Maritime Architecture Research and Technology, Qingdao University of Technology, Fushun Road 11, Qingdao 266033, China
Yoshiaki Ushifusa: Faculty of Economics and Business Administration, The University of Kitakyushu, Kitakyushu 802-8577, Japan
Yingjun Ruan: Institute of Mechanical Engineering, Tongji University, Siping Road 1239, Shanghai 200092, China
IJERPH, 2021, vol. 18, issue 13, 1-19
Abstract:
ZEHs (Zero Energy House) featuring energy-efficient designs and on-site renewable integration are being widely developed. This study introduced Japanese ZEHs with well-insulated thermal envelopes and investigated their detailed operational performances through on-site measurements and simulation models. Measurement data show that ZEHs effectively damped the variation of indoor air temperature compared to conventional houses, presenting great ability to retain inside heat energy, and are expected to potentially deliver energy flexibility as a virtual thermal energy storage medium. We developed a simplified thermal resistance–capacitance model for a house heating system; response behaviors were simulated under various scenarios. Results compared the variations of indoor temperature profiles and revealed the dependence of load flexibility on the building’s overall heat loss performance. We observed that overall heat loss rate played a crucial role in building heat energy storage efficiency; a well-insulated house shortened the heat-up time with less energy input, and extended the delayed period of indoor temperature under intermittent heating supply; a high set-point operative temperature and a low ambient temperature led to lower virtual thermal energy storage efficiency. The preheating strategy was simulated as an effective load-shifting approach in consuming surplus PV generation; approximately 50% of consumed PV generation could be shifted to replace grid import electricity for room heating during the occupied period.
Keywords: zero energy house; operational performance; virtual energy storage; load flexibility (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1660-4601/18/13/6782/pdf (application/pdf)
https://www.mdpi.com/1660-4601/18/13/6782/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:18:y:2021:i:13:p:6782-:d:581188
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().