Test–Retest Reliability of Functional Electromechanical Dynamometer on Five Sit-to-Stand Measures in Healthy Young Adults
Daniel Jerez-Mayorga,
Álvaro Huerta-Ojeda,
Luis Javier Chirosa-Ríos,
Francisco Guede-Rojas,
Iris Paola Guzmán-Guzmán,
Leonardo Intelangelo,
Claudia Miranda-Fuentes and
Pedro Delgado-Floody
Additional contact information
Daniel Jerez-Mayorga: Faculty of Rehabilitation Sciences, Universidad Andres Bello, Santiago 7591538, Chile
Álvaro Huerta-Ojeda: Grupo de Investigación en Salud, Actividad Física y Deporte ISAFYD, Universidad de Las Américas, Sede Viña del Mar 2531098, Chile
Luis Javier Chirosa-Ríos: Department Physical Education and Sports, Faculty of Sport Sciences, University of Granada, 18011 Granada, Spain
Francisco Guede-Rojas: Faculty of Rehabilitation Sciences, Universidad Andres Bello, Concepción 4030000, Chile
Iris Paola Guzmán-Guzmán: Faculty of Chemical-Biological Sciences, Universidad Autόnoma de Guerrero, Chilpancingo 39087, Mexico
Leonardo Intelangelo: Musculoskeletal Research Group, University Center for Assistance, Teaching and Research, University of Gran Rosario, Rosario 2000, Argentina
Claudia Miranda-Fuentes: Faculty of Rehabilitation Sciences, Universidad Andres Bello, Santiago 7591538, Chile
Pedro Delgado-Floody: Department of Physical Education, Sports and Recreation, Universidad de La Frontera, Temuco 4811230, Chile
IJERPH, 2021, vol. 18, issue 13, 1-12
Abstract:
Background: The purpose of this study was to determine the reliability for the strength and movement velocity of the concentric phase from the five Sit-to-Stand (5STS), using three incremental loads measured by a functional electromechanical dynamometer (FEMD) in healthy young adults. Methods: The average and peak strength and velocity values of sixteen healthy adults (mean ± standard deviation (SD): age = 22.81 ± 2.13 years) were recorded at 5, 10 and 15 kg. To evaluate the reliability of FEMD, the intraclass correlation coefficient (ICC), standard error of measurement (SEM) and coefficient of variation (CV) were obtained. Results : Reliability was high for the 10 kg (CV range: 3.70–4.18%, ICC range: 0.95–0.98) and 15 kg conditions (CV range: 1.64–3.02%, ICC: 0.99) at average and peak strength, and reliability was high for the 5 kg (CV range: 1.71–2.84%, ICC range: 0.96–0.99), 10 kg (CV range: 0.74–1.84%, ICC range: 0.99–1.00) and 15 kg conditions (CV range: 0.79–3.11%, ICC range: 0.99–1.00) at average and peak velocity. Conclusions: The findings of this study demonstrate that FEMD is a reliable instrument to measure the average and peak strength and velocity values during the five STS in healthy young adults.
Keywords: reproducibility; isokinetic; muscle (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1660-4601/18/13/6829/pdf (application/pdf)
https://www.mdpi.com/1660-4601/18/13/6829/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:18:y:2021:i:13:p:6829-:d:582238
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().