EconPapers    
Economics at your fingertips  
 

Radiofrequency Exposure Levels from Mobile Phone Base Stations in Outdoor Environments and an Underground Shopping Mall in Japan

Teruo Onishi, Miwa Ikuyo, Kazuhiro Tobita, Sen Liu, Masao Taki and Soichi Watanabe
Additional contact information
Teruo Onishi: National Institute of Information and Communications Technology, Tokyo 184-8795, Japan
Miwa Ikuyo: National Institute of Information and Communications Technology, Tokyo 184-8795, Japan
Kazuhiro Tobita: National Institute of Information and Communications Technology, Tokyo 184-8795, Japan
Sen Liu: National Institute of Information and Communications Technology, Tokyo 184-8795, Japan
Masao Taki: National Institute of Information and Communications Technology, Tokyo 184-8795, Japan
Soichi Watanabe: National Institute of Information and Communications Technology, Tokyo 184-8795, Japan

IJERPH, 2021, vol. 18, issue 15, 1-10

Abstract: Recent progress in wireless technologies has made human exposure to electromagnetic fields (EMFs) increasingly complex. The situation can increase public concerns related to possible health effects due to EMF exposure. Monitoring EMF exposure levels and characterizing them are indispensable for risk communications of human exposure to EMFs. From this background, a project on the acquisition, accumulation, and applications of EMF exposure monitoring data in Japan was started in 2019. One of the objectives of this project is to obtain a comprehensive picture of EMF exposure in actual daily lives. In 2019 and 2020, we measured the electric field (E-field) strength from mainly mobile phone base stations in the same areas as those in measurements conducted in 2006 and 2007 by the Ministry of Internal Affairs and Communications (MIC), Japan, and compared the data to investigate the time-course of the EMF environment. The number of measured points was 100 (10 × 10 grids) in an area of 1 km × 1 km in two urban and two suburban areas, and that in an underground shopping mall was 158. This large-scale study is the first in Japan. As a result, we found that the measured E-field strengths tended to be higher in 2019 and 2020 than those in 2006 and 2007, especially in the mall. However, the median ratios to the Japanese radio wave protection guideline values for urban areas and malls are lower than ?40 dB.

Keywords: EMF exposure levels; monitoring; mobile base stations; outdoor environment; underground shopping mall; Japan (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1660-4601/18/15/8068/pdf (application/pdf)
https://www.mdpi.com/1660-4601/18/15/8068/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:18:y:2021:i:15:p:8068-:d:604793

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:18:y:2021:i:15:p:8068-:d:604793