Microbial Air Monitoring in Turbulent Airflow Operating Theatres: Is It Possible to Calculate and Hypothesize New Benchmarks for Microbial Air Load?

Maria Luisa Cristina, Anna Maria Spagnolo, Gianluca Ottria, Elisa Schinca, Chiara Dupont, Alessio Carbone, Martino Oliva and Marina Sartini
Additional contact information
Maria Luisa Cristina: Department of Health Sciences, University of Genova, Via Pastore 1, 16132 Genova, Italy
Anna Maria Spagnolo: Department of Health Sciences, University of Genova, Via Pastore 1, 16132 Genova, Italy
Gianluca Ottria: Department of Health Sciences, University of Genova, Via Pastore 1, 16132 Genova, Italy
Elisa Schinca: Department of Health Sciences, University of Genova, Via Pastore 1, 16132 Genova, Italy
Chiara Dupont: Department of Health Sciences, University of Genova, Via Pastore 1, 16132 Genova, Italy
Alessio Carbone: Operating Unit (S.S.D. U.O.) Hospital Hygiene, Galliera Hospital, Mura delle Cappuccine 14, 16128 Genoa, Italy
Martino Oliva: Operating Unit (S.S.D. U.O.) Hospital Hygiene, Galliera Hospital, Mura delle Cappuccine 14, 16128 Genoa, Italy
Marina Sartini: Department of Health Sciences, University of Genova, Via Pastore 1, 16132 Genova, Italy

IJERPH, 2021, vol. 18, issue 19, 1-12

Abstract: Multiple studies have demonstrated the presence of microorganisms commonly associated with surgical site infections (SSIs), in the air within the operating theatre (OT). In some countries such Italy, the limit of microbial concentration in the air for OT with turbulent airflows is 35 CFU/m 3 for an empty OT and 180 CFU/m 3 during activity. This study aims to hypothesize new benchmarks for the airborne microbial load in turbulent airflow operating theatres in operational and at rest conditions using the percentile distribution of data through a 17-year environmental monitoring campaign in various Italian hospitals that implemented a continuous quality improvement policy. The quartile distribution analysis has shown how in operational and at rest conditions, 75% of the values were below 110 CFU/m 3 and 18 CFU/m 3 , respectively, which can be considered a new benchmark for the monitored OTs. During the initial stages of the monitoring campaign, 28.14% of the concentration values in operational conditions and 29.29% of the values in at rest conditions did not conform to the Italian guidelines’ reference values. In contrast, during the last 5 years, all values in both conditions conformed to the reference values and 98.94% of these values were below the new benchmarks. Continuous improvement has allowed contamination to be reduced to levels well below the current reference values.

Keywords: surgical site infections; benchmark for microbial airborne concentration; turbulent airflow operating theatres (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1660-4601/18/19/10379/pdf (application/pdf)
https://www.mdpi.com/1660-4601/18/19/10379/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:18:y:2021:i:19:p:10379-:d:648710

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:18:y:2021:i:19:p:10379-:d:648710