EconPapers    
Economics at your fingertips  
 

Foot Position Measurement during Assistive Motion for Sit-to-Stand Using a Single Inertial Sensor and Shoe-Type Force Sensors

Kodai Kitagawa, Ibai Gorordo Fernandez, Takayuki Nagasaki, Sota Nakano, Mitsumasa Hida, Shogo Okamatsu and Chikamune Wada
Additional contact information
Kodai Kitagawa: Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, 2–4 Hibikino, Wakamatsu-ku, Kitakyushu 808-0196, Japan
Ibai Gorordo Fernandez: Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, 2–4 Hibikino, Wakamatsu-ku, Kitakyushu 808-0196, Japan
Takayuki Nagasaki: Department of Rehabilitation, Tohoku Bunka Gakuen University, 6-45-1 Kunimi, Aoba-ku, Sendai 981-8551, Japan
Sota Nakano: Department of Rehabilitation, Kyushu University of Nursing and Social Welfare, 888 Tomio, Tamana 865-0062, Japan
Mitsumasa Hida: Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, 2–4 Hibikino, Wakamatsu-ku, Kitakyushu 808-0196, Japan
Shogo Okamatsu: Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, 2–4 Hibikino, Wakamatsu-ku, Kitakyushu 808-0196, Japan
Chikamune Wada: Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, 2–4 Hibikino, Wakamatsu-ku, Kitakyushu 808-0196, Japan

IJERPH, 2021, vol. 18, issue 19, 1-18

Abstract: Assistive motion for sit-to-stand causes lower back pain (LBP) among caregivers. Considering previous studies that showed that foot position adjustment could reduce lumbar load during assistive motion for sit-to-stand, quantitative monitoring of and instructions on foot position could contribute toward reducing LBP among caregivers. The present study proposes and evaluates a new method for the quantitative measurement of foot position during assistive motion for sit-to-stand using a few wearable sensors that are not limited to the measurement area. The proposed method measures quantitative foot position (anteroposterior and mediolateral distance between both feet) through a machine learning technique using features obtained from only a single inertial sensor on the trunk and shoe-type force sensors. During the experiment, the accuracy of the proposed method was investigated by comparing the obtained values with those from an optical motion capture system. The results showed that the proposed method produced only minor errors (less than 6.5% of body height) when measuring foot position during assistive motion for sit-to-stand. Furthermore, Bland–Altman plots suggested no fixed errors between the proposed method and the optical motion capture system. These results suggest that the proposed method could be utilized for measuring foot position during assistive motion for sit-to-stand.

Keywords: foot position; assistive motion; sit-to-stand; wearable sensor; force sensor; inertial sensor; machine learning technique (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2021
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1660-4601/18/19/10481/pdf (application/pdf)
https://www.mdpi.com/1660-4601/18/19/10481/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:18:y:2021:i:19:p:10481-:d:650448

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:18:y:2021:i:19:p:10481-:d:650448