Primary and Secondary Emissions of VOCs and PAHs in Indoor Air from a Waterproof Coal-Tar Membrane: Diagnosis and Remediation
Rafael Piñeiro,
Eva Jimenez-Relinque,
Roman Nevshupa and
Marta Castellote
Additional contact information
Rafael Piñeiro: Institute of Construction Science “Eduardo Torroja”, IETcc (CSIC), 28033 Madrid, Spain
Eva Jimenez-Relinque: Institute of Construction Science “Eduardo Torroja”, IETcc (CSIC), 28033 Madrid, Spain
Roman Nevshupa: Institute of Construction Science “Eduardo Torroja”, IETcc (CSIC), 28033 Madrid, Spain
Marta Castellote: Institute of Construction Science “Eduardo Torroja”, IETcc (CSIC), 28033 Madrid, Spain
IJERPH, 2021, vol. 18, issue 23, 1-15
Abstract:
Primary and secondary emissions of volatile organic compounds (VOCs) and polycyclic aromatic hydrocarbons (PAHs) from a waterproof coal tar membrane and their effect on the indoor air quality were investigated through a case study in a residential building situated in Madrid, Spain. The air contaminants were analyzed in situ using photoionization method and several samples of contaminants were taken using three sorbents: activated carbon, XAD2 and Tenax GR. It was found that various VOCs such as toluene, p- and m-Xylene, PAHs such as naphthalene, methyl-naphthalenes, acenaphthene, acenaphthylene, phenanthrene and fluorine, volatile organic halogens including chloroform and trichlorofluoromethane, and alkylbenzene (1,2,4-trimethylbenzene) were found at concentrations, which exceeded the limits established by international and national agencies (WHO, EPA, OSHA). Some of the above organic compounds were found also in the samples of construction and building materials, which were obtained at different heights and places. The analysis of possible sources of the contaminants pointed at the original coal-tar membrane, which was applied on the terrace to be waterproof. During a posterior reparation the membrane was coated with a new one that hindered dissipation of emitted contaminants. The contaminants leached out and were absorbed by construction materials down in the dwelling. These materials then acted as secondary emission sources. To remediate the emission problem as the contaminated materials were removed and then a ventilation system was installed to force the gasses being emitted from the rest of contaminated slab outside. Follow-up has validated the success of the remediation procedure.
Keywords: VOCs; PAHs; emissions; indoor; coal-tar membrane; terrace; diagnosis; remediation (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2021
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1660-4601/18/23/12855/pdf (application/pdf)
https://www.mdpi.com/1660-4601/18/23/12855/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:18:y:2021:i:23:p:12855-:d:696202
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().