The Reliability of Pelvic Floor Muscle Bioelectrical Activity (sEMG) Assessment Using a Multi-Activity Measurement Protocol in Young Women
Łukasz Oleksy,
Anna Mika,
Iwona Sulowska-Daszyk,
Ewelina Rosłoniec,
Renata Kielnar and
Artur Stolarczyk
Additional contact information
Łukasz Oleksy: Orthopaedic and Rehabilitation Department, Medical University of Warsaw, 02-091 Warsaw, Poland
Anna Mika: Institute of Clinical Rehabilitation, University of Physical Education in Kraków, Al. Jana Pawła II 78, 31-571 Krakow, Poland
Iwona Sulowska-Daszyk: Institute of Clinical Rehabilitation, University of Physical Education in Kraków, Al. Jana Pawła II 78, 31-571 Krakow, Poland
Ewelina Rosłoniec: Department of Physiotherapy, Poznań University of Physical Education, 66-400 Gorzów Wielkopolski, Poland
Renata Kielnar: Institute of Health Sciences, Medical College of Rzeszów University, 35-315 Rzeszów, Poland
Artur Stolarczyk: Orthopaedic and Rehabilitation Department, Medical University of Warsaw, 02-091 Warsaw, Poland
IJERPH, 2021, vol. 18, issue 2, 1-13
Abstract:
The aim of the study was to determine the between-trial and between-day reliability of the Glazer protocol and our multi-activity surface electromyography (sEMG) measurement protocol for pelvic floor muscle (PFM) evaluation. The bioelectrical activity of PFM was collected using an endovaginal electrode in 30 young, Caucasian, nulliparous women (age 22–27, 168.6 ± 5.1 cm, 57.1 ± 11.8 kg). The between-trial and between-day reliability of the original Glazer protocol and the new multi-activity sEMG protocol were assessed during the following phases: pre-baseline rest, phasic (flick) contractions, tonic contractions, endurance contraction, and post-baseline rest. The Glazer protocol was characterized by poor and moderate measurement reliability. The time-domain parameters for the rise and fall of the signal amplitude and median frequency showed poor between-trial and between-day reliability. The mean and peak amplitudes indicated mainly good between-trial and moderate between-days reliability. Our protocol showed moderate to excellent reliability of both time-domain and quantitative parameters of muscle recruitment. In our protocol, the frequency-domain parameters describing muscle fatigue demonstrated much higher reliability than in the case of the Glazer protocol. The most important information obtained in this study was the significant improvement of diagnostic validity in PFM bioelectrical activity evaluation. The higher reliability of our sEMG protocol compared to original Glazer protocol allowed us to suggest that protocol modifications and changes in sEMG signal processing methods were effective in the improvement of PFM assessment quality. The new parameters calculated from the sEMG signal proposed in our sEMG protocol allowed us to obtain additional clinically important information about PFM dysfunctions regarding specific deficits of muscle contraction such as decrease in muscle strength; endurance or coordination related to, e.g., stress urinary incontinence; or pelvic floor muscle imbalance after childbirth.
Keywords: surface electromyography (sEMG); pelvic floor muscles; Glazer protocol; multi-activity sEMG protocol; reliability (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2021
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1660-4601/18/2/765/pdf (application/pdf)
https://www.mdpi.com/1660-4601/18/2/765/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:18:y:2021:i:2:p:765-:d:482100
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().