Test–Retest Reliability of an iPhone ® Inclinometer Application to Assess the Lumbar Joint Repositioning Error in Non-Specific Chronic Low Back Pain
Alejandro Caña-Pino,
Luís Espejo-Antúnez,
José Carmelo Adsuar and
María Dolores Apolo-Arenas
Additional contact information
Alejandro Caña-Pino: Department of Medical Surgical-Therapy, Medicine Faculty, Extremadura University, 06006 Badajoz, Spain
Luís Espejo-Antúnez: Department of Medical Surgical-Therapy, Medicine Faculty, Extremadura University, 06006 Badajoz, Spain
José Carmelo Adsuar: Promoting a Healthy Society Research Group, Faculty of Sport Sciences, University of Extremadura, 10003 Cáceres, Spain
María Dolores Apolo-Arenas: Department of Medical Surgical-Therapy, Medicine Faculty, Extremadura University, 06006 Badajoz, Spain
IJERPH, 2021, vol. 18, issue 5, 1-11
Abstract:
Background: The joint position sense (JPS) has been used as an indirect marker of proprioception in subjects with non-specific chronic low back pain (NSCLBP), showing impairment in previous studies. It seems necessary to devise reliable tests to measure proprioceptive deficits in subjects with NSLBP. The objective of this study was to analyse the test–retest reliability and smallest real difference (SRD) of lumbar proprioception through the JPS indicator in a sample of patients with NSCLBP. Methods: Fifty participants with NSCLBP performed three repetitions of 30° lumbar flexion while standing and sitting using the iPhone ® inclinometer application to measure the lumbar joint repositioning error. For the reliability analysis, we performed an intra-session test–retest. Results : The total sample ICC values were excellent for standing (0.96) and sitting (0.93) 30° lumbar flexion. In addition, our results showed that, for the total sample, an SRD < 12% can be considered as a true change in proprioception concerning this procedure. On the other hand, men have better reliability than women in both standing and sitting positions. Additionally, the sitting position has better reliability than the standing position. The standard error of measurement (SEM) percentage was 4.2 for standing and 3.8 for sitting. The SRD percentage was 11.6 for standing and 10.4 for sitting. Conclusions: The iPhone ® inclinometer seems reliable for assessing proprioceptive ability through the lumbar joint repositioning error in subjects with NSCLBP in both standing (ICC = 0.96) and sitting (ICC = 0.93) positions. This technological device showed a lower measurement error for sitting position (SRD < 12%).
Keywords: non-specific low back pain; proprioception; joint position sense; reliability; smart phone (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2021
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1660-4601/18/5/2489/pdf (application/pdf)
https://www.mdpi.com/1660-4601/18/5/2489/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:18:y:2021:i:5:p:2489-:d:509757
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().