Validation of a High Flow Rate Puff Topography System Designed for Measurement of Sub-Ohm, Third Generation Electronic Nicotine Delivery Systems
Evan Floyd,
Toluwanimi Oni,
Changjie Cai,
Bilal Rehman,
Jooyeon Hwang and
Tyler Watson
Additional contact information
Evan Floyd: Department of Occupational and Environmental Health, Hudson College of Public Health, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
Toluwanimi Oni: Department of Occupational and Environmental Health, Hudson College of Public Health, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
Changjie Cai: Department of Occupational and Environmental Health, Hudson College of Public Health, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
Bilal Rehman: University of Oklahoma Health Sciences Center, University of Oklahoma College of Medicine, Oklahoma City, OK 73104, USA
Jooyeon Hwang: Department of Occupational and Environmental Health, Hudson College of Public Health, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
Tyler Watson: Department of Occupational and Environmental Health, Hudson College of Public Health, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104, USA
IJERPH, 2022, vol. 19, issue 13, 1-12
Abstract:
There are few known puff topography devices designed solely for gathering electronic cigarette puff topography information, and none made for high-powered sub-ohm devices. Ten replicate Bernoulli flow cells were designed and 3D printed. The relationship between square root of pressure difference and flow rate was determined across 0–70 L/min. One representative flow cell was used to estimate puff volume and flow rate under six simulated puffing regimes (0.710 L, 2.000 L and 3.000 L, at low and high flow rates) to determine the system’s accuracy and utility of using dual pressure sensors for flow measurement. The relationship between flow rate and square root of pressure differential for the ten replicate cells was best fit with a quadratic model (R 2 = 0.9991, p < 0.0001). The higher-pressure sensor was accurate at both low and high flow rates for 0.71 L (102% and 111% respectively), 2.00 L (96% and 103% respectively), and 3.00 L (100.1% and 107% respectively) but the lower-pressure sensor provided no utility, underpredicting volume and flow. This puff topography system generates very little resistance to flow, easily fits between user’s atomizer and mouthpiece, and is calibrated to measure flows up to 70 L/min.
Keywords: electronic nicotine delivery systems; high flow rate puff topography; flow cell; tobacco regulatory control (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1660-4601/19/13/7989/pdf (application/pdf)
https://www.mdpi.com/1660-4601/19/13/7989/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:19:y:2022:i:13:p:7989-:d:851685
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().