Development of a Manual Measurement Device for Measuring Hallux Valgus Angle in Patients with Hallux Valgus
Guoli Li,
Jinsong Shen,
Edward Smith and
Chetna Patel
Additional contact information
Guoli Li: School of Art and Design, Guangzhou Panyu Polytechnic, Guangzhou 511483, China
Jinsong Shen: Textile Engineering and Materials Research Group, School of Fashion and Textiles, De Montfort University, Leicester LE1 9BH, UK
Edward Smith: Textile Engineering and Materials Research Group, School of Fashion and Textiles, De Montfort University, Leicester LE1 9BH, UK
Chetna Patel: The Maths Learning Centre, De Montfort University, Leicester LE1 9BH, UK
IJERPH, 2022, vol. 19, issue 15, 1-11
Abstract:
Background: Hallux valgus (HV) is one of the most common forefoot deformities, and its prevalence increases with age. HV has been associated with poor foot function, difficulty in fitting footwear and poor health-related quality of life. The aims of this study were to design and develop an easy-to-use measurement device for measuring hallux valgus angle (HVA) in patients with HV and to assess the measurement reliability of the newly designed measurement device. Methods: A manual measurement device for measuring HVA was designed and developed to test on patients with HV. Two measuring methods, i.e., test–retest and intra-observer measurements, were used to evaluate the repeatability and reliability of the newly designed measurement device. In the test–retest measurements, a total of 42 feet from 26 patients with HV were repeatedly measured by the same researcher using the manual measurement device every 3 weeks over a period of 12 months. The measurement reliability of the newly designed measurement device was analysed based on the collected HVA data. In the intra-observer measurements, a total of 22 feet from the same group of HV patients were measured by the same researcher using the manual measurement device and by a consultant using X-ray measurement for comparison. The intraclass correlation coefficient (ICC) was used to determine the correlation of measurements between the manual measurement device and X-ray measurement. Results: The mean of the difference between the two repeat measurements of HVA using the newly designed manual device was 0.62°, and the average of ICC was 0.995, which indicates excellent reliability. The ICC between X-ray and the average of twice-repeated manual measurements was 0.868, with 95% CI (0.649, 0.947) ( p = 0.000). When the relationship in HVA between X-ray measurement and manual measurement using the new device was regressed as a linear relationship, the regression equation was y = 1.13x − 4.76 (R 2 = 0.70). Conclusions: The newly designed measurement device is easy to use, with low-cost and excellent reliability for HVA measurement, with the potential for use in clinical practice.
Keywords: radiograph measurement; manual measurement; hallux valgus angular measurement; manual measurement device; reliability (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1660-4601/19/15/9108/pdf (application/pdf)
https://www.mdpi.com/1660-4601/19/15/9108/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:19:y:2022:i:15:p:9108-:d:872067
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().