Influence of the Internal Structure Type of a Large-Area Lower Exhaust Workbench on Its Surface Air Distribution
Jianwu Chen (),
Longzhe Jin (),
Bin Yang,
Zhenfang Chen and
Guoliang Zhang
Additional contact information
Jianwu Chen: School of Civil and Resource Engineering, University of Science and Technology Beijing, Beijing 100083, China
Longzhe Jin: School of Civil and Resource Engineering, University of Science and Technology Beijing, Beijing 100083, China
Bin Yang: School of Civil and Resource Engineering, University of Science and Technology Beijing, Beijing 100083, China
Zhenfang Chen: Institute of Occupational Health, China Academy of Safety Science and Technology, Beijing 100012, China
Guoliang Zhang: School of Civil and Resource Engineering, University of Science and Technology Beijing, Beijing 100083, China
IJERPH, 2022, vol. 19, issue 18, 1-14
Abstract:
Local exhaust ventilation is an important method of contamination control, and the type of exhaust hood and the air distribution at the hood face have an important influence on the contamination control effect. When the hood face is large, it is difficult to create a uniform airflow distribution at the hood face, which if achieved, could improve the effect of contamination control. To that end, the large-area workbench used in the process of vaccine purification was taken as the research subject prototype for this study. According to the methods for generating a uniform airflow distribution at the hood face, the lower exhaust workbenches of four structures were established using CAD and simulated using Ansys Fluent. The best uniformity of workbench surface air distribution was with Structure-4, while the worst was with Structure-1. The workbench surface airflow distribution could not achieve uniformity when only an inclined bottom was used for the large-area lower exhaust workbench with one side outlet. The more internal slits there were, the greater the air distribution area and the more uniform the air distribution. The width of the area of workbench surface airflow distribution was determined by the width of the slits. The numerical simulation results were verified by experiments, which showed them to be credible.
Keywords: lower exhaust hood; airflow distribution; uniform airflow; contamination control; workbench (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)
Downloads: (external link)
https://www.mdpi.com/1660-4601/19/18/11395/pdf (application/pdf)
https://www.mdpi.com/1660-4601/19/18/11395/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:19:y:2022:i:18:p:11395-:d:911666
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().