EconPapers    
Economics at your fingertips  
 

Three-Dimensional Comparison of the Maxillary Surfaces through ICP-Type Algorithm: Accuracy Evaluation of CAD/CAM Technologies in Orthognathic Surgery

Andrea Cassoni, Luigi Manganiello (), Giorgio Barbera, Paolo Priore, Maria Teresa Fadda, Resi Pucci and Valentino Valentini
Additional contact information
Andrea Cassoni: Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy
Luigi Manganiello: Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy
Giorgio Barbera: Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy
Paolo Priore: Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy
Maria Teresa Fadda: Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy
Resi Pucci: Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy
Valentino Valentini: Department of Oral and Maxillofacial Sciences, Sapienza University of Rome, Via Caserta 6, 00161 Rome, Italy

IJERPH, 2022, vol. 19, issue 18, 1-10

Abstract: Purpose: This retrospective study aims to compare the accuracy of two different CAD/CAM systems in orthognathic surgery. The novelty of this work lies in the method of evaluating the accuracy, i.e., using an Iterative Closest Point (ICP) algorithm, which matches a pair of 2D or 3D point clouds with unknown dependencies of the transition from scan s (k) to scan s (k+1) . Methods: The study population was composed of ten patients who presented to the Maxillofacial Surgery Department of the University “Sapienza” of Rome for the evaluation and management of skeletal malocclusions. The patients were divided into two groups, depending on the technique used: group 1: splintless group (custom-made cutting guide and plates); group 2: splint group (using a 3D-printed splint). STL files were imported into Geomagic ® Control X™ software, which allows for comparison and analysis using an ICP algorithm. The RMSE parameter (3D error) was used to calculate the accuracy. In addition, data were compared in two different patient subgroups. The first subgroup only underwent a monobloc Le Fort I osteotomy ( p -value = 0.02), and the second subgroup underwent a Le Fort I osteotomy associated with a segmental osteotomy of the maxilla ( p -value = 0.23). Results: Group 1 showed a 3D error of 1.22 mm ± SD 0.456, while group 2 showed a 3D error of 1.63 mm ± SD 0.303. These results have allowed us to compare the accuracy of the two CAD/CAM systems ( p -value = 0.09). Conclusions: The ICP algorithm provided a reproducible method of comparison. The splintless method would seem more accurate ( p -value = 0.02) in transferring the surgical programming into the operating room when only a Le Fort I osteotomy is to be performed.

Keywords: ICP algorithm; orthognathic surgery; virtual surgical planning; CAD/CAM; splint; patient-specific implant (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1660-4601/19/18/11834/pdf (application/pdf)
https://www.mdpi.com/1660-4601/19/18/11834/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:19:y:2022:i:18:p:11834-:d:919175

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:19:y:2022:i:18:p:11834-:d:919175