High-Level Mobility of Trans-Tibial Prosthesis Users Wearing Commercial and sPace Energy-Storing Prosthetic Feet
Thanyaporn Rakbangboon,
Gary Guerra (),
Saloottra Kla-arsa,
Uthumporn Padungjaroen,
Pairat Tangpornprasert,
Chanyaphan Virulsri and
Kazuhiko Sasaki
Additional contact information
Thanyaporn Rakbangboon: Sirindhorn School of Prosthetics and Orthotics, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand
Gary Guerra: Department of Exercise and Sport Science, St. Mary’s University, San Antonio, TX 78228, USA
Saloottra Kla-arsa: Sirindhorn School of Prosthetics and Orthotics, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand
Uthumporn Padungjaroen: Sirindhorn School of Prosthetics and Orthotics, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand
Pairat Tangpornprasert: Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok 10330, Thailand
Chanyaphan Virulsri: Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok 10330, Thailand
Kazuhiko Sasaki: Sirindhorn School of Prosthetics and Orthotics, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok 10700, Thailand
IJERPH, 2022, vol. 19, issue 19, 1-11
Abstract:
Outcomes of users provided with a commercial ESR Vari-Flex foot (Össur, Reykjavik, Iceland) and a locally designed sPace foot were investigated. Step activity with users’ own prosthetic foot compared to the sPace foot was explored. Methods: Eleven individuals with unilateral trans-tibial amputation participated and were provided with an sPace and Vari-Flex foot. Ten- and twenty-meter walk tests (10/20MWT) at comfortable and fast walking speeds (CWS/FWS), the two-minute walk test (2-MWT) and Comprehensive High-Level Activity Mobility Predictor (CHAMP) were administered. A subgroup was provided a pedometer to record their steps over a 7-day period in their own foot and later the sPace. Results: The sPace foot performed well in a battery of high-level mobility outcome measures. On CHAMP, participants scored 16.94 ± 5.41 and 16.72 ± 6.09 with the sPace and Vari-Flex feet, respectively. Subgroup testing of step activity showed 4490 ± 3444 steps in users’ own feet and 3115 ± 1967 in the sPace foot, p = 0.176. Conclusions: Participants using the sPace foot were capable of performing walking, high-level mobility and activity outcome measures.
Keywords: prosthesis; foot; energy storing and return; two-minute walk test; sPace; CHAMP (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1660-4601/19/19/12606/pdf (application/pdf)
https://www.mdpi.com/1660-4601/19/19/12606/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:19:y:2022:i:19:p:12606-:d:932223
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().