Comparing a Sensor for Movement Assessment with Traditional Physiotherapeutic Assessment Methods in Patients after Knee Surgery—A Method Comparison and Reproducibility Study
Jennifer Eymann,
Werner Vach (),
Luis Fischer,
Marcel Jakob and
Andreas Gösele
Additional contact information
Jennifer Eymann: Crossklinik AG, 4054 Basel, Switzerland
Werner Vach: Basel Academy for Quality and Research in Medicine, 4051 Basel, Switzerland
Luis Fischer: Crossphysio, 4054 Basel, Switzerland
Marcel Jakob: Crossklinik AG, 4054 Basel, Switzerland
Andreas Gösele: Crossklinik AG, 4054 Basel, Switzerland
IJERPH, 2022, vol. 19, issue 24, 1-19
Abstract:
Wearable sensors offer the opportunity for patients to perform a self-assessment of their function with respect to a variety of movement exercises. Corresponding commercial products have the potential to change the communication between patients and physiotherapists during the recovery process. Even if they turn out to be user-friendly, there remains the question to what degree the numerical results are reliable and comparable with those obtained by assessment methods traditionally used. To address this question for one specific recently developed and commercially available sensor, a method comparison study was performed. The sensor-based assessment of eight movement parameters was compared with an assessment of the same parameters based on test procedures traditionally used. Thirty-three patients recovering after arthroscopic knee surgery participated in the study. The whole assessment procedure was repeated. Reproducibility and agreement were quantified by the intra class correlation coefficient. The height of a one-leg vertical jump and the number of side hops showed high agreement between the two modalities and high reproducibility (ICC > 0.85). Due to differences in the set-up of the assessment, agreement could not be achieved for three mobility parameters, but even the correlation was only fair (r < 0.5). Knee stability showed poor agreement. Consequently, the use of the sensor can currently only be recommended for selected parameters. The variation in degree of agreement and reproducibility across different parameters clearly indicate the need for developing corresponding guidance for each new sensor put onto the market.
Keywords: wearable sensor; movement exercises; assessment; agreement; reproducibility (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1660-4601/19/24/16581/pdf (application/pdf)
https://www.mdpi.com/1660-4601/19/24/16581/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:19:y:2022:i:24:p:16581-:d:999150
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().