Self-Administered Six-Minute Walk Test Using a Free Smartphone App in Asymptomatic Adults: Reliability and Reproducibility
Matheus Oliveira de Jesus,
Thatiane Lopes Valentim Di Paschoale Ostolin,
Neli Leite Proença,
Rodrigo Pereira da Silva and
Victor Zuniga Dourado
Additional contact information
Matheus Oliveira de Jesus: Department of Human Movement Sciences, Federal University of São Paulo (UNIFESP), Santos 11015-020, SP, Brazil
Thatiane Lopes Valentim Di Paschoale Ostolin: Department of Human Movement Sciences, Federal University of São Paulo (UNIFESP), Santos 11015-020, SP, Brazil
Neli Leite Proença: Department of Human Movement Sciences, Federal University of São Paulo (UNIFESP), Santos 11015-020, SP, Brazil
Rodrigo Pereira da Silva: Department of Human Movement Sciences, Federal University of São Paulo (UNIFESP), Santos 11015-020, SP, Brazil
Victor Zuniga Dourado: Department of Human Movement Sciences, Federal University of São Paulo (UNIFESP), Santos 11015-020, SP, Brazil
IJERPH, 2022, vol. 19, issue 3, 1-13
Abstract:
Background: The 6-min walk test (6MWT) is a simple, inexpensive, reliable, and reproducible test that provides a reasonable estimate of the cardiorespiratory fitness (CRF). We aimed to assess the reliability and reproducibility of a self-administered 6MWT in asymptomatic adults using a free smartphone app. Methods: In the 1st phase, 93 participants underwent a supervised 6MWT (6MWTsup) in a 30 m indoor corridor, using a triaxial accelerometer and their smartphones to compare the total step counts and to develop a 6-min walk distance (6MWD) prediction equation. In the 2nd phase, 25 participants performed the 6MWTsup and two self-administered 6MWTs outdoors (6MWTsa1 and 6MWTsa2, at least 48 h apart) using a free smartphone app. Results: The agreement between accelerometer- and app-based total step counts was limited (mean difference, −58.7 steps (−8.7%): 95% confidence interval, −326.5 (−46.8%) to 209.1 (29.3%)). The best algorithm for predicting the 6MWTsup m included: 795.456 + (0.815 height m app-steps) − (1.620 age years ) − (3.005 weight kg ) − (1.155 app-steps), R 2 = 0.609). The intraclass correlation coefficient between 6MWTsa2 and 6MWTsa1 was excellent (0.91: 0.81–0.96). The coefficient of variation was 6.4%. The agreement between the two self-administered tests was narrow (−1.9 (0.2%) meters: −57.4 (−9.5%) to 61.3 (9.9%)). Conclusions: The self-administered 6MWT has excellent reliability and reproducibility in asymptomatic adults, being a valuable tool for assessing CRF in community-based interventions.
Keywords: cardiorespiratory fitness; accelerometer; 6-minute walk test; physical activity level; health and public health; app; applications (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations: View citations in EconPapers (1)
Downloads: (external link)
https://www.mdpi.com/1660-4601/19/3/1118/pdf (application/pdf)
https://www.mdpi.com/1660-4601/19/3/1118/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:19:y:2022:i:3:p:1118-:d:728937
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().