EconPapers    
Economics at your fingertips  
 

Analysis of Ventilation Efficiency as Simultaneous Control of Radon and Carbon Dioxide Levels in Indoor Air Applying Transient Modelling

Mateja Dovjak, Ožbej Vene and Janja Vaupotič
Additional contact information
Mateja Dovjak: Buildings and Constructional Complexes, Faculty of Civil and Geodetic Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia
Ožbej Vene: Buildings and Constructional Complexes, Faculty of Civil and Geodetic Engineering, University of Ljubljana, 1000 Ljubljana, Slovenia
Janja Vaupotič: Department of Environmental Sciences, Jožef Stefan Institute, 1000 Ljubljana, Slovenia

IJERPH, 2022, vol. 19, issue 4, 1-20

Abstract: The impact of ventilation efficiency on radon ( 222 Rn) and carbon dioxide (CO 2 ) concentrations in the indoor air of a residential building was studied by applying transient data analysis within the CONTAM 3.4 program. Continuous measurements of 222 Rn and CO 2 concentrations, together with basic meteorological parameters, were carried out in an apartment (floor area about 27 m 2 ) located in Ljubljana, Slovenia. Throughout the experiment (October 3–15), frequent ventilation (several times per day), poor ventilation (once to twice per day) and no ventilation scenarios were applied, and the exact ventilation and occupancy schedule were recorded. Based on the measurements, a transient simulation of 222 Rn and CO 2 concentrations was performed for six sets of scenarios, where the design ventilation rate (DVR) varied based on the ventilation requirements and recommendations. On the days of frequent ventilation, a moderate correlation between the measured and simulated concentrations ( r = 0.62 for 222 Rn, r = 0.55 for CO 2 ) was found. The results of the simulation indicated the following optimal DVRs: (i) 36.6 m 3 h −1 (0.5 air changes per hour, ACH) to ensure a CO 2 concentration below 1000 ppm and a 222 Rn concentration below 100 Bq m −3 ; and (ii) 46.9 m 3 h −1 (0.7 ACH) to ensure a CO 2 concentration below 800 ppm. These levels are the most compatible with the 5C_Cat I (category I of indoor environmental quality, defined by EN 16798-1:2019) scenario, which resulted in concentrations of 656 ± 121 ppm for CO 2 and 57 ± 13 Bq m −3 for 222 Rn. The approach presented is applicable to various types of residential buildings with high overcrowding rates, where a sufficient amount of air volume to achieve category I indoor environmental quality has to be provided. Lower CO 2 and 222 Rn concentrations indoors minimise health risk, which is especially important for protecting sensitive and fragile occupants.

Keywords: ventilation; residential buildings; transient modelling; radon; carbon dioxide (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2022
References: View references in EconPapers View complete reference list from CitEc
Citations: View citations in EconPapers (2)

Downloads: (external link)
https://www.mdpi.com/1660-4601/19/4/2125/pdf (application/pdf)
https://www.mdpi.com/1660-4601/19/4/2125/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:19:y:2022:i:4:p:2125-:d:748766

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:19:y:2022:i:4:p:2125-:d:748766