EconPapers    
Economics at your fingertips  
 

Efficacy of AutoPulse for Mechanical Chest Compression in Patients with Shock-Resistant Ventricular Fibrillation

Jarosław Gorący, Paweł Stachowiak, Arkadiusz Krejczy, Patrycja Piątek and Iwona Gorący
Additional contact information
Jarosław Gorący: Independent Laboratory of Invasive Cardiology, Pomeranian Medical University in Szczecin, 70-204 Szczecin, Poland
Paweł Stachowiak: Department of Cardiology, The Regional Specialist Hospital in Wrocław, Research and Development Center, 51-124 Wrocław, Poland
Arkadiusz Krejczy: Province Emergency Medical Services, 71-011 Szczecin, Poland
Patrycja Piątek: Department of Cardiology, Pomeranian Medical University, 70-111 Szczecin, Poland
Iwona Gorący: Department of Clinical and Molecular Biochemistry, Pomeranian Medical University, 70-111 Szczecin, Poland

IJERPH, 2022, vol. 19, issue 5, 1-10

Abstract: Introduction: Sudden cardiac arrest is one of the most common causes of death. In cases of shock-resistant ventricular fibrillation, immediate transport of patients to the hospital is essential and made possible with use of devices for mechanical chest compression. Objectives: The efficacy of AutoPulse in patients with shock-resistant ventricular fibrillation was studied. Methods: This is a multicentre observational study on a population of 480,000, with 192 reported cases of out-of-hospital cardiac arrest. The study included patients with shock-resistant ventricular fibrillation defined as cardiac arrest secondary to ventricular fibrillation requiring ≥3 consecutive shocks. Eventually, 18 patients met the study criteria. Results: The mean duration of resuscitation was 48.4±43 min, 55% of patients were handed over to the laboratory while still in cardiac arrest, 83.3% of them underwent angiography and, in 93.3% of them, infarction was confirmed. Coronary intervention was continued during mechanical resuscitation in 50.0% of patients, 60% of patients survived the procedure, and 27.8% of the patients survived. Conclusions: Resistant ventricular fibrillation suggests high likelihood of a coronary component to the cardiac arrest. AutoPulse is helpful in conducting resuscitation, allowing the time to arrival at hospital to be reduced.

Keywords: cardiac arrest; catheterization laboratory; mechanical chest compression; PCI; ventricular fibrillation (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1660-4601/19/5/2557/pdf (application/pdf)
https://www.mdpi.com/1660-4601/19/5/2557/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:19:y:2022:i:5:p:2557-:d:756102

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:19:y:2022:i:5:p:2557-:d:756102