UV-C Light-Based Surface Disinfection: Analysis of Its Virucidal Efficacy Using a Bacteriophage Model
Stefan A. Rudhart,
Frank Günther,
Laura Dapper,
Boris A. Stuck and
Stephan Hoch
Additional contact information
Stefan A. Rudhart: Department of Otolaryngology, Head and Neck Surgery, University Hospital Marburg, Philipps-University Marburg, 35043 Marburg, Germany
Frank Günther: Department of Medical Microbiology and Hygiene, University Hospital Marburg, Philipps-University Marburg, 35043 Marburg, Germany
Laura Dapper: Department of Medical Microbiology and Hygiene, University Hospital Marburg, Philipps-University Marburg, 35043 Marburg, Germany
Boris A. Stuck: Department of Otolaryngology, Head and Neck Surgery, University Hospital Marburg, Philipps-University Marburg, 35043 Marburg, Germany
Stephan Hoch: Department of Otolaryngology, Head and Neck Surgery, University Hospital Marburg, Philipps-University Marburg, 35043 Marburg, Germany
IJERPH, 2022, vol. 19, issue 6, 1-9
Abstract:
Background: The reprocessing of medical devices has become more complex due to increasing hygiene requirements. Previous studies showed satisfactory bactericidal disinfection effects of UV-C light in rigid and flexible endoscopes. Especially in the context of the current COVID-19 pandemic, virucidal properties are of high importance. In the present study, the virucidal efficacy of UV-C light surface disinfection was analyzed. Methods: MS-2 bacteriophages were applied to the test samples and irradiated by UV-C light using the UV Smart D25 device; unirradiated test samples were used as controls. A dilution series of the samples was mixed with 1 × 10 8 Escherichia coli and assayed. Results: 8.6 × 10 12 pfu could be harvested from the unprocessed test samples. In the control group without UV-C exposure, a remaining contamination of 1.2 × 10 12 pfu was detected, resulting in a procedural baseline reduction rate with a LOG 10 reduction factor of 0.72. The LOG 10 reduction factor was found to be 3.0 after 25 s of UV-C light exposure. After 50 and 75 s of UV-C radiation LOG 10 reduction factors 4.2 and 5.9, respectively, were found, with all reductions being statistically significantly different to baseline. Conclusions: The tested UV system seems to provide a significant virucidal effect after a relatively short irradiation time.
Keywords: endoscopes; otorhinolaryngology; COVID-19; MS-2; UV light; D25; disinfection; surface disinfection; virus; adenovirus (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations:
Downloads: (external link)
https://www.mdpi.com/1660-4601/19/6/3246/pdf (application/pdf)
https://www.mdpi.com/1660-4601/19/6/3246/ (text/html)
Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.
Export reference: BibTeX
RIS (EndNote, ProCite, RefMan)
HTML/Text
Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:19:y:2022:i:6:p:3246-:d:767835
Access Statistics for this article
IJERPH is currently edited by Ms. Jenna Liu
More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().