Accuracy of Fetal Biacromial Diameter and Derived Ultrasonographic Parameters to Predict Shoulder Dystocia: A Prospective Observational Study

Marco La Verde, Pasquale De Franciscis, Clelia Torre, Angela Celardo, Giulia Grassini, Rossella Papa, Stefano Cianci, Carlo Capristo, Maddalena Morlando and Gaetano Riemma
Additional contact information
Marco La Verde: Obstetrics and Gynecology Unit, Department of Woman, Child and General and Specialized Surgery, University of Campania “Luigi Vanvitelli”, 80128 Naples, Italy
Pasquale De Franciscis: Obstetrics and Gynecology Unit, Department of Woman, Child and General and Specialized Surgery, University of Campania “Luigi Vanvitelli”, 80128 Naples, Italy
Clelia Torre: Obstetrics and Gynecology Unit, Department of Woman, Child and General and Specialized Surgery, University of Campania “Luigi Vanvitelli”, 80128 Naples, Italy
Angela Celardo: Obstetrics and Gynecology Unit, Department of Woman, Child and General and Specialized Surgery, University of Campania “Luigi Vanvitelli”, 80128 Naples, Italy
Giulia Grassini: Obstetrics and Gynecology Unit, Department of Woman, Child and General and Specialized Surgery, University of Campania “Luigi Vanvitelli”, 80128 Naples, Italy
Rossella Papa: Obstetrics and Gynecology Unit, Department of Woman, Child and General and Specialized Surgery, University of Campania “Luigi Vanvitelli”, 80128 Naples, Italy
Stefano Cianci: Unit of Gynecology and Obstetrics, Department of Human Pathology of Adult and Childhood “G. Barresi”, University of Messina, 98122 Messina, Italy
Carlo Capristo: Pediatrics Unit, Department of Woman, Child and General and Specialized Surgery, University of Campania “Luigi Vanvitelli”, 80128 Naples, Italy
Maddalena Morlando: Obstetrics and Gynecology Unit, Department of Woman, Child and General and Specialized Surgery, University of Campania “Luigi Vanvitelli”, 80128 Naples, Italy
Gaetano Riemma: Obstetrics and Gynecology Unit, Department of Woman, Child and General and Specialized Surgery, University of Campania “Luigi Vanvitelli”, 80128 Naples, Italy

IJERPH, 2022, vol. 19, issue 9, 1-10

Abstract: Background and Objectives: Shoulder dystocia (ShD) is one of most dangerous obstetric complication. The objective of this study was to determine if the ultrasonographic fetal biacromial diameter (BA) and derived parameters could predict ShD in uncomplicated term pregnancies. Materials and Methods: We conducted a prospective observational study in a tertiary care university hospital from March 2021 to February 2022. We included all full-term pregnancies accepted for delivery that received an accurate ultrasonography (USG) scan before delivery. USG biometry and estimated fetal weight (EFW) were collected. Therefore, we evaluated the diameter of the mid-arm, the transverse thoracic diameter (TTD) and the biacromial diameter (BA). BA was estimated using Youssef’s formula: TTD + 2 mid-arm diameters. The primary outcome was the evaluation of BA and its related parameters (BA/biparietal diameter (BPD), BA/head circumference (HC) and BA–BPD in fetuses with ShD versus fetuses without ShD. Diagnostic accuracy for ShD of BA, BA/BPD, BA/HC and BA–BPD was evaluated using receiver operator curve (ROC) analysis. Results: 90 women were included in the analysis, four of these had ShD and required extra maneuvers after head delivery. BA was increased in fetuses with ShD (150.4 cm; 95% CI 133.2 cm to 167.6 cm) compared to no-ShD (133.5 cm; 95% CI 130.1 cm to 137.0 cm; p = 0.04). Significant differences were also found between ShD and no-ShD groups for BA/BPD (1.66 (95% CI 1.46 to 1.86) vs. 1.44 (95% CI 1.41 to 1.48); p = 0.04), BA/HC (0.45 (95% CI 0.40 to 0.49) vs. 0.39 (95% CI 0.38 to 0.40); p = 0.01), BA–BPD (60.0 mm (95% CI 42.4 to 77.6 cm) vs. 41.4 (95% CI 38.2 to 44.6); p = 0.03), respectively. ROC analysis showed an overall good accuracy for ShD, with an AUC of 0.821 ( p = 0.001) for BA alone and 0.881 ( p = 0.001), 0.857 ( p = 0.016) and 0.867 ( p = 0.013) for BA/BPD, BA–BPD and BA/HC, respectively. Conclusions: BA alone, as well as BA/BPD, BA/HC and BA–BPD might be useful predictors of ShD in uncomplicated term pregnancies. However, such evidence needs extensive confirmation by means of additional studies with large sample sizes, especially in case of pregnancies at high risk for ShD (i.e., gestational diabetes).

Keywords: shoulder dystocia; fetal biacromial diameter; ultrasound fetal biacromial diameter; fetal ultrasound biometry; delivery; fetal macrosomia (search for similar items in EconPapers)
JEL-codes: I I1 I3 Q Q5 (search for similar items in EconPapers)
Date: 2022
References: View complete reference list from CitEc
Citations:

Downloads: (external link)
https://www.mdpi.com/1660-4601/19/9/5747/pdf (application/pdf)
https://www.mdpi.com/1660-4601/19/9/5747/ (text/html)

Related works:
This item may be available elsewhere in EconPapers: Search for items with the same title.

Export reference: BibTeX RIS (EndNote, ProCite, RefMan) HTML/Text

Persistent link: https://EconPapers.repec.org/RePEc:gam:jijerp:v:19:y:2022:i:9:p:5747-:d:811302

Access Statistics for this article

IJERPH is currently edited by Ms. Jenna Liu

More articles in IJERPH from MDPI
Bibliographic data for series maintained by MDPI Indexing Manager ().

 
Page updated 2025-03-19
Handle: RePEc:gam:jijerp:v:19:y:2022:i:9:p:5747-:d:811302